PSEN cs2.2n
Operating Manual PSEN cs2.2n
1003367-EN-04
16
Table of error codes
Error code
Decimal
Number of flashes
Description
Remedy
1.4.1
3x short – 1x long – 4x
long – 1x long – 3x short
Wiring error
Rectify wiring error
1.12
3x short – 1x long – 12x
long – 3x short
Wiring error
Rectify wiring error
1.13
3x short – 1x long – 12x
long – 3x short
Wiring error
Rectify wiring error
14
3x short – 14x long – 3x
short
Wiring error
Rectify wiring error
15
3x short – 15x long – 3x
short
Wiring error
Rectify wiring error
Other flashing codes signal an internal error. Remedy: Change device.