Operation
Initialisation Process
•
When the unit is powered on, the green LED will illuminate.
•
The remaining three lights will flash and an intermittent
audible alarm will sound for approximately 30 seconds.
•
The initialisation process may take up to 8 minutes. However,
after the 30 seconds the intermittent alarm will stop.
•
If one or both of the sensors have not stabilised yet, the LEDs
will continue to flash.
•
During the stabilisation process, the sounder will do a longer
beep once for each sensor when it has completed stabilisation.
•
If the number of beeps does not correspond to the number of
sensors connected, switch off the system and check all
connections.
•
If the audible alarm continues to sound after the initialisation
process immediate action must be taken:
1.
Ensure that nothing is used which could ignite gas e.g.
matches, engine ignition etc.
2.
Ventilate the area by opening doors and hatches
3.
Investigate and remove any source of dangerous vapour.
4.
The Pilot Gas Alarm will stop alarming once the vapour
has been safely removed.
7