4. 

Instructions for using piezoelectrical elements and power 
supplies 

 

Piezoelectric  actuators  from 

piezosystem  jena

  are  controlled  by  voltages 

up  to  150V.  These  values  can  be  quite  hazardous.  Therefore  read  the 
installation  instructions  carefully.  Only  authorized  personal  should  handle 
the power supply. 

 

After  transportation,  piezoelectric  actuators  should  be  allowed  to  adapt  for 

approximately 2 hours to the room temperature before being switched on. 

 

Piezoelectric  actuators  are  made  from  ceramic  materials  with  and  without 

metallic  casings.  The  piezo-ceramic  is  a  relatively  brittle  material.  This 
should be noted when handling piezoelectrical actuators. All piezo-elements 
are sensitive to bending or shock forces. 

 

Due  to  the  piezoelectric  effect,  piezo-actuators  can  generate  electrical 

charges  by  changing  the  mechanical  load  or  the  temperature  or  such 
actions described above. 

 

Piezoelectric actuators are able to work under high compressive forces, only 

actuators with pre-load can be used under tensile loads (these tensile forces 
must be less then the pre-load, given in the data sheet). 

 

Please  note  that  the  acceleration  of  the  ceramic  material  (e.g.,  caused  by 

fall  down,  discharging  or  high  dynamic  application)  can  cause  damage  to 
the actuator. 

 

Heating  of  the  ceramic  material  will  occur  during  dynamic  operation  and  is 

caused by structure conditional loss processes. This may cause failure if the 
temperature exceeds specified values cited below. 

 

With  increasing  temperature,  up  to  the  Curie  temperature  (usual  values 

approx. 140°C - 250°C), the piezoelectric effect disappears. 

 

Piezoelectric actuators such as stacks or various tables work electrically as 

a  capacitance.  These  elements  are  able  to  store  electrical  energy  over  a 
long period (up to some days) and the stored energy may be dangerous. 

 

If  the  actuator  remains  connected  to  the  drive  electronics,  it  is  discharged 

within  a  second  after  shutdown  and  quickly  reaches  harmless  voltage 
values. 

 

Piezo-actuators  can  generate  voltages  by  warming  or  cooling  only.  The 

discharge potential should not be ignored due to the inner capacitance. This 
effect is insignificant at usual room temperature. 

 

Piezo-actuators  from 

piezosystem  jena

  are  adjusted  and  glued.  Any 

opening of the unit will cause misalignment or possible malfunction and the 
guarantee will become invalid. 

 

Please  contact 

piezosystem  jena

  or  your  local  representative,  if  there  are 

any problems with your actuator or power supply. 
Caution!  Shock  forces  may  damage  the  built-in  ceramic  element.  Please 
avoid such forces, and handle the units with care, otherwise the guarantee 
will become invalid. 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for 12V40 Series

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...

Page 2: ...41 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 17 Instruction Manual Voltage Amplifier 12V40 Series Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...nstructions for checking the function of the system quick start 23 7 How to operate the 12V40 24 7 1 Technical data 24 7 2 Initialization 25 7 3 Service 25 7 4 SMB modulation input MOD 26 7 5 SMB monitor output socket MON 26 7 6 Actuator socket OUT 26 7 7 Switch closed loop 12V40SG 12V40CLE 26 7 8 Wiring of the rear panel connector 27 7 9 Possibilities of the error correction 29 8 Your notes 30 Ar...

Page 4: ...ries contains following amplifiers 12V40 12V40SG 12V40CLE 24V40 24V40SG 24V40CLE 12V40C und 12V40CSG This manual also offers you additional information about piezoelectric products 2 Certification of piezosystem jena The company piezosystem jena GmbH has been certified by DIN EN ISO 9001 2000 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 5: ...Tel 49 0 3641 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 20 3 Declaration of conformity Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 6: ...plication can cause damage to the actuator Heating of the ceramic material will occur during dynamic operation and is caused by structure conditional loss processes This may cause failure if the temperature exceeds specified values cited below With increasing temperature up to the Curie temperature usual values approx 140 C 250 C the piezoelectric effect disappears Piezoelectric actuators such as ...

Page 7: ...or unstable cart stand or table as they may fall or not work accurately Work with the units only in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please use only original parts from piezosystem jena piezosystem jena does not give any warranty for damages or malfunction caused by additional parts not supplied by piezosystem jena Additional c...

Page 8: ...hipment The secondary voltage DC matches with the amplifier Connect the power cable Connect the piezo element by using the LEMO connector Turn off closed loop 12V40SG 12V40CLE Switch on the power supply The red LED indicates the amplifier is working By turning the potentiometer to its maximum position the actuator will reach its maximum movement Offset is accomplished by the offset potentiometer o...

Page 9: ...0 5A 24V DC dimensions BxHxT mm 173mm x 130mm 105mm x 45mm mass g 800 channels 1 output power W 6 output current mA 40 output voltage OUT 10 150 V output connector OUT LEMO 0S 302 modulation input MOD 0 10V SMB inner resistance 10kΩ monitor voltage MON 1 15V SMB 0 10V on SG CLE 0 10V rear panel Inner resistance 100kΩ SMB 10kΩ rear panel output noise 0 3 mVRMS 500Hz bandwidth Hz 400 polarity positi...

Page 10: ... the ceramics and increase the MTBF In addition the OVL LED lights up in the case of a limit error No automatic disconnection of the overvoltage occurs in that case To guarantee stable temperature circumstances we recommend to switch on the amplifier approx 2 hours before the measurement in the sub µm range takes place A constant temperature environment is necessary for precise positioning tasks P...

Page 11: ...nt devices 100kΩ should be used The output is short protected please avoid injected voltages 12V40SG 12V40CLE The measuring voltage 0 10V is available at this socket and can be monitored by using an analogue oscilloscope This is especially recommended for dynamical operation Pay attention to the inner resistance of the monitor output only high ohmic measurement 100kΩ devices should be used The out...

Page 12: ... control by HIGH or LOW TTL level HIGH Pin 7 is active OFFSET potentiometer and MOD modulation input at the front panel are switched off LOW Pin 7 is not active motion of the actuator will be controlled by the OFFSET potentiometer and the MOD modulation input at the front panel 12 OUT output voltage Uout 10 150V option 15 GND ground operating voltage 16 PWR operating voltage table 2 pin wiring of ...

Page 13: ...rol by HIGH or LOW TTL level HIGH Pin 7 is active OFFSET potentiometer and MOD modulation input at the front panel are switched off LOW Pin 7 is not active motion of the actuator will be controlled by the OFFSET potentiometer and the MOD modulation input at the front panel 24 OUT output voltage Uout 10 150V option 30 GND ground operating voltage 32 PWR operating voltage table 3 pin wiring of the r...

Page 14: ...ease check the modulation input and offset table 4 possibilities of the error correction The equipment concept makes adaptations to customer preferences concerning the technical threshold values such as the main voltage or the output voltage possible Please contact our technical service department in order to discover the possibilities for your specific problem Any adjustments necessary are to be ...

Page 15: ...Tel 49 0 3641 66880 Fax 49 0 3641 668866 info piezojena com www piezosystem de 30 8 Your notes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 16: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: