SAFETY FEATURES
The machine is equipped with an Emergency Switch Off Button
. The power supply to the motor is cut off
when the Emergency Switch Off Button is pushed. Always make sure the Emergency Switch Off Button is
pressed or completely unplug the machine when the machine accessories (e.g. Cutter or Grinding Chains)
are not inside a pipe. Always unplug the machine from the power source when performing any
maintenance or repairs to the machine.
The machine is operated by foot pedal (Operator Presence Control or ‘OPC’)
. When the control is not
held down the machine stops. Never place any kind of object on the pedal in place of a foot (such as a
brick).
Power Plugs
For safety purposes
only use grounded outlets. If the plug does not fit securely or match the outlet
do not force it
—
contact an electrician to determine required power supply. Never alter the plug in any way. Use the plug with an ex-
tension cord only if it can be fully inserted into the receptacle. Use the Mini Cleaner or Mini CC with a heavy
duty extension cord only.
If a power generator is used as power source ensure that the power rating is sufficient.
220
-
230V:
EU Schuko 230 V 16 A. Power cable lead minimum thickness 1.5mm
2
.
110
-
125V:
The Mini Cleaner and Mini CC is equipped with a 16 amp (125V) NEMA 16 amp plug. Power
cable lead minimum thickness 2.5 mm
2
/ 14 AWG. The Mini Cleaner and Mini CC must be
supplied with sufficient power and proper current rating. A minimum of 15 amps are needed to
operate it safely and effciently. When used with an extension cord, the cord must be a 3 prong, 16
amp (125 V). If power generator is used, minimum 3 kW required. Adapters may be necessary for
generator connections. Contact your Reseller or Picote technical support for more information.
AUSTRALIA/UK:
Mini Cleaners & Mini ClC in these regions have special plugs.
Australia:
CEE 16 A 230 V colour blue. Power cable minimum lead thickness 2.5 mm
2
.
UK:
UK Plug BSEN 60309 16 A 110 V colour yellow. Power cable lead minimum thickness 2.5 mm
2
.
The Mini Cleaner and Mini CC requires a transformer to comply with the site power
regulations and safe usage in UK.
NOTE: If working with a generator always use the 110 V transformer. Do not plug directly in to the
generator.
Ensure that the supply voltage is correct
. The voltage of the power source must match the value given on the name-
plate of the machine within the tolerances of ±10 %. Machines with a 230V plate can be used in 220V mains and
110V machines in the 120V grid.
The machine has been double sealed according to European standards. The power source has to be grounded.
Camera power supply can operate with Input: 110VAC ~ 240 VAC, Output:12V DC 1200mA . The DVR unit has in
-
built
5200 mAh Li
-
ion battery (7.4 V).