Summary of Contents for 6100000020

Page 1: ...nstructions are for your personal safety Always ensure that you have read and understood these instructions before using the machinery SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE We now have resellers in the U S Europe Australasia Locate your reseller at picotesolutions com ...

Page 2: ...ARTS 11 WARRANTY POLICY PROCEDURE 12 To watch practical demonstration videos or to download an electronic copy of these In structions please visit www picotesolutions com Please note that videos are not intend ed as a replacement or alternative to this operating and safety manual but only as an additional learning tool TABLE OF CONTENTS ...

Page 3: ...accident are prevented Always tranport Sentinel inside the vehicle STORAGE Sentinel Guard 2 0 should be strored under cover in condensation frost free environment It is recemmended that Senti nel units are stored indoors protected from rain and sunlight and in and constant ambient temperature If Sentinel will be stored in colder environment than 10 o C 50 o F the machine should be stood at room te...

Page 4: ...es 4 Do not open the lid of the Sentinel Guard after the SIM card has been placed inside 5 If the working environment is extremely hot and humid or badly polluted by conductive dust use a GFCI enabled power outlet to ensure the safety of the operator 6 Always check the internet connection quality prior to use the Sentinel Guard 2 0 7 Only use the Sentinel Guard 2 0 with the accessories and spare p...

Page 5: ...pply 3 Monitoring water level in pumping stations 4 Monitoring temperature Sentinel 2 0 has a built in remote alarm feature This allows it to send an alert message to a mobile phone in cases of power outage fluctuation of the pressure outside the limits or water level in a pumping station rise too high The alerts will be sent by calling text messages via the GSM network and email User can also che...

Page 6: ...o send alarm messages in the event of power failure and is NOT a substitute for the mains power supply VOLTAGE POWER SUPPLY Sentinel Guard uses a Mini sized SIM card The SIM card slot is found under the lid Once the SIM card has been in serted inside the lid should be closed at all times Before inserting the SIM card into the Sentinel Guard 2 0 the PIN code lock must be turned off This can be done...

Page 7: ...aligned The power and water sensor connectors have protective covers that are meant to be used when the connector is not in use START UP To begin using the Sentinel Guard 2 0 device connect it to a mains power socket using the provided cable Always connect the power supply provided to the Sentinel Guard 2 0unit The unit has a back up battery as well but it is only intended as a back up for pressur...

Page 8: ...hoenix onos fi LOGGIN INTO THE SENTINEL 2 0 STEP 2 Insert the username and password that were provided with the device STEP 3 Click on the Home button STEP 4 Click on the Phoenix you want to control STEP 5 You will now see the main view of your Sentinel Guard 2 0 ...

Page 9: ...corner you will find a panel titled ADD ALERT ADDRESS STEP 3 To add a phone number insert the phone number with the country code STEP 4 After typing phone number click ADD To add an email address insert the email address STEP 5 Verify that the alert addresses are now listed in the ALERT ADDRESSES panel above ...

Page 10: ...ttom left corner you will find a panel titled REMOVE ALERT ADDRESS STEP 3 To remove a phone number insert the phone number with the country code STEP 4 To remove an email address insert the email address STEP 5 Verify that the alert address you removed is no longer listed in the ALERT ADDRESSES panel ...

Page 11: ...d if the pressure drops below the set limit after a 30 second delay STEP 1 Log into your Sentinel Guard 2 0 as per section Logging into the Phoenix STEP 2 In the top left corner you will find a panel titled LIMIT STEP 3 Insert your desired pressure limit in kPa Use pressure converter to change psi or bar values into kPa STEP 4 Click on the SET button STEP 5 Check that the pressure limit has change...

Page 12: ...r is lost or the 4G signal of the Phoenix is lost There is a 3 minute delay in the power failure alert STEP 1 Up to a hundred water level sensors can be connected to the Sentinel Guard 2 0 STEP 2 The high water level alert is always enabled STEP 3 The alert will be fired if the water level sensor detects too high a water level STEP 4 The current status of the sensor can be seen on the TEMPERATURE ...

Page 13: ...13 STEP 1 Historical data can be browsed by clicking on the time frame on the upper right corner ...

Page 14: ...em that you cannot solve using this manual please consult Picote Solutions Oy Ltd You must use only the Picote Solutions accessories and attachments with the Sentinel Guard 2 0 described in this operations manual If failed to comply the machine may not work as intended Note that the warranty of the product may also be violated ACCESSORIES SPARE PARTS 6100000020 Sentinel Liner Guard 2 0 Type 1 EU 6...

Page 15: ...rts accessories or third party products when using the Products or 6 the use of the Products not in compliance with their respective Documentation user manuals safety and maintenance instructions and any usage restrictions contained therein or 7 accident fire power failure power surge or other hazard Otherwise the Products are sold AS IS End User is responsible for using the Products within their ...

Page 16: ...wn picotesolutions com Anthony DeCavitch Global Sales Director 1 219 440 1404 tony picotesolutions com Authorised Resellers www picotesolutions com resellers Jake Saltzman World Wide Technical Director 1 706 436 1892 jake picotesolutions com Richard Swan Director of Technical Client Services 44 0 7827 223237 richard picotesolutions com Raudoittajantie 4 06450 Porvoo Finland support picotesolutions...