13
Trigger Output Monitor
The trigger output signal is generated with an integrated, isolated Rogowski coil and
provides an ultra fast galvanically isolated signal. The signal shape is proportional to the
derivative of the load current. It can be used for a current response triggering signal and
has no delay to the load current. Combined with an integrator it is possible to use this
signal for a galvanically isolated current monitor.
Current Consumption
Quiescent currents
Supply input
Conditions
Min.
Max.
Unit
+5 V
4.8 V .. 5.2 V
TBD
TBD
mA
HV
0 V .. 55 V
5
400
mA
Trigger signal present
Supply input Conditions
Typ.
Max.
Unit
EN / EP
-
0.3
5
mA
EN
Differential input
low threshold
-30
-100
mV
EP
Differential input
high threshold
-30
0
mV
Cooling
The driver is base plate cooled only. Please assemble the entire unit to a heat sink which is
capable to take out the heat.
The heat sink is suitable if the system temperature does not exceed the maximum operating
limits.
Power Losses
Due the structure of this driver the power losses of this driver can be approximately
estimated with following equation
A
W
V
I
t
f
V
P
HV
out
pw
rep
HV
LOSS
/
07
.
0
⋅
+
⋅
⋅
⋅
≈
+
+
Where
LOSS
P
Total average power consumption [W]
+
HV
V
High voltage supply [V]
rep
f
Repetition frequency [Hz]
pw
t
Optical pulse width [s]
out
I
Output current [A]