3.15. 

Technical specifications

Voltage range, operating

3 V to 690 V AC (950 V DC)

Overvoltage protection

CAT IV 600 V, CAT III 1000 V relative to earth (ground)

Indicators

Audible alarm and light

Display counts

1000 

Input resistance

700 kΩ at 50 V AC

Frequency

50/60 Hz ± 3%

Operating temperature

−15 °C to +45 °C (class N)

Storage temperature

−15 °C to +55 °C

Pollution degree

2

Altitude

2000 m max

Relative humidity

95% RH max

Safety

See the 

PicoScope

®

 4225A and 4425A automotive oscilloscope and 

accessories Safety Guide

 for the complete safety information.

Ingress protection

IP65

Shock

1 J max.

Batteries supplied

2 x AAA (1.5 V)

Operating cycle, on

30 s

(maximum time for which the device can be connected to the maximum operating voltage)

Operating cycle, off

240 s

(minimum idle time for the device to cool down after operating cycle, on, during which the detector must not be 

connected to an energized part)
Storage

In a clean, dry place

Location of use

Indoor/outdoor use

Weight

220 g

Accuracy

(±5% ±2 digits)

Resolution 

1 V

Summary of Contents for TA466

Page 1: ...User s guide TA466 Two pole voltage detector www picoauto com...

Page 2: ...Battery level indicator 4 3 4 AC or DC voltage verification and measurement 4 3 5 Polarity check direct voltage 5 3 6 Phase neutral check alternating voltages 5 3 7 Phase order check three phase syst...

Page 3: ...use on standard European outlets centre to centre distance 19 mm The voltage detector has the following features polarity indicator Audible continuity indicator 100 Phase order indicator in a three ph...

Page 4: ...tative to arrange the return Note 2 The correct operation check function is there to make sure that the test leads battery and electronic circuit integrity are working and correct 3 3 Battery level in...

Page 5: ...rmine the phase order in a three phase system You perform this operation in two sequences using the two test probes First make sure that there is voltage present and that it has the same value for eac...

Page 6: ...test button 3 10 Battery replacement Make sure that the device is disconnected from all voltage sources The battery must be replaced when the correct operation check self test fails 1 Use a Pozidriv s...

Page 7: ...bris and to recreate and or increase the insulation clean the device with a cloth coated with silicone MO984 Change the batteries Perform daily inspection Note For any non compliance during the period...

Page 8: ...V AC 950 V DC Overvoltage protection CAT IV 600 V CAT III 1000 V relative to earth ground Indicators Audible alarm and light Display counts 1000 Input resistance 700 k at 50 V AC Frequency 50 60 Hz 3...