3.8. Continuity check

Perform this operation in power-off mode.
Place the two test probes at the terminals of the item you want to check and press the test button .
A continuity resistance of less than 100 Ω is indicated by:

•  A red backlight on the display.
•  A rapidly pulsating  audible signal.

A continuity resistance of more than 100 Ω will cause the voltage detector to show no indication.

3.9. Pocket lamp function

Press the test button.

3.10. 

Battery replacement

Make sure that the device is disconnected from all voltage sources. 
The battery must be replaced when the correct operation check (self-test) fails.

1. 

Use a Pozidriv screwdriver to undo the three screws on the bottom cover.

2. 

Remove the bottom cover.

3. 

Insert two AAA batteries (LR03: 1.5 V), make sure you observe the polarity indicated on the 

battery holder.

4. 

Replace the bottom cover. Take care to reposition the joint before you tighten the three screws.

5. 

Secure with an adequate torque (about 0.75 Nm).

Note 1: Remove the batteries if the voltage detector will be unused for a longer period of time.
Note 2: The batteries have an expiration date indicated on the body. Replace them before they 

expire.

Summary of Contents for TA466

Page 1: ...User s guide TA466 Two pole voltage detector www picoauto com...

Page 2: ...Battery level indicator 4 3 4 AC or DC voltage verification and measurement 4 3 5 Polarity check direct voltage 5 3 6 Phase neutral check alternating voltages 5 3 7 Phase order check three phase syst...

Page 3: ...use on standard European outlets centre to centre distance 19 mm The voltage detector has the following features polarity indicator Audible continuity indicator 100 Phase order indicator in a three ph...

Page 4: ...tative to arrange the return Note 2 The correct operation check function is there to make sure that the test leads battery and electronic circuit integrity are working and correct 3 3 Battery level in...

Page 5: ...rmine the phase order in a three phase system You perform this operation in two sequences using the two test probes First make sure that there is voltage present and that it has the same value for eac...

Page 6: ...test button 3 10 Battery replacement Make sure that the device is disconnected from all voltage sources The battery must be replaced when the correct operation check self test fails 1 Use a Pozidriv s...

Page 7: ...bris and to recreate and or increase the insulation clean the device with a cloth coated with silicone MO984 Change the batteries Perform daily inspection Note For any non compliance during the period...

Page 8: ...V AC 950 V DC Overvoltage protection CAT IV 600 V CAT III 1000 V relative to earth ground Indicators Audible alarm and light Display counts 1000 Input resistance 700 k at 50 V AC Frequency 50 60 Hz 3...

Reviews: