PICO TA386 User Manual Download Page 3

Symbols

These safety and electrical symbols may appear on the product or in this guide:

Symbol Description

Direct current

Earth (ground) terminal

Terminal can be used to make a 

measurement ground connection. 

The terminal is NOT a safety or 

protective earth.

Possibility of electric shock

Caution

Appearance on the product 

indicates a need to read these 

safety and operation instructions.

Do not dispose of this product 

as unsorted municipal waste.

WARNING

To prevent injury or death only qualified personnel should use this 

product, only as instructed and with only accessories supplied or 

recommended. Protection provided by the product may be impaired if 

used in a manner not specified in this guide.

Maximum input ranges

The table and frequency derating plot below indicate the full-scale measurement 

range and overvoltage protection range for these probes. The full-scale 

measurement ranges are the maximum voltages that can be accurately 

measured by the probe. The overvoltage protection ranges are the maximum 

voltages that will not damage the probe.

WARNING

To prevent electric shock, do not connect the probe to voltages exceeding 

the levels below and do take all necessary safety precautions when 

working on equipment where hazardous live voltages may be present.

Attenuation 

switch position

Full-scale measurement 

range (for safe operation)

Overvoltage protection 

(voltage that will not damage)

X10

600 V DC + peak AC

600 V DC + peak AC

X1

42.4 V DC + peak AC

200 V DC + peak AC

WARNING

To avoid overloading the probe, note that its maximum input voltage 

rating decreases as the frequency of the applied signal increases. 

Summary of Contents for TA386

Page 1: ...User s Guide TA386 X1 X10 Max 600 Vp X 1 X 1 0 TA375 100 MHz oscilloscope probe TA386 200 MHz oscilloscope probe...

Page 2: ...es including damages for loss of profits loss of business loss of use or data interruption of business and the like even if Pico has been advised of the possibility of such damages arising from any de...

Page 3: ...input ranges The table and frequency derating plot below indicate the full scale measurement range and overvoltage protection range for these probes The full scale measurement ranges are the maximum v...

Page 4: ...ng WARNING Never connect the ground input to or allow it to touch any electrical potential other than ground To prevent personal injury or death use a voltmeter to check that there is no significant A...

Page 5: ...There may be a charge for these services unless covered by the Pico two year warranty WARNING To prevent injury or death do not use the product if it appears to be damaged in any way and stop use imme...

Page 6: ...ntil you see a flat top square wave on the display CORRECT INCORRECT INCORRECT Accessories and features The probe is provided with several accessories designed to make probing and measurement simpler...

Page 7: ...Ground lead Use the alligator clip to attach the probe to a ground reference Hook tip Spring loaded for gripping wires and test points Adjustment tool Use to adjust the probe compensation BNC connect...

Page 8: ...0 MHz 200 MHz Rise time calculated 35 ns 3 5 ns 35 ns 1 75 ns Input resistance 1M 10 M 2 1M 10 M 2 Input capacitance 57 pF CS 15 pF 57 pF CS 15 pF Max working voltage 42 4 V pk 600 V pk pk 42 4 V pk 6...

Reviews: