background image

NVH Interface

PicoDiagnostics

Quick Start Guide

®

PicoDiagnostics NVH interface 

Pico Technology

DO210-9

6. 

Troubleshooting 

Problem

Check

Action

NVH Interface not 

working

Is the LED 

ƽEWLMRK#

Yes

Check BNC lead

No

Connect/change sensor
Check sensor connection to interface is secure
Check battery orientation
Replace battery

7. 

7TIGMƼGEXMSRW

Weight: 

NVH Interface

 

Accelerometer

 

Microphone

120 g

80 g

20 g

Dimensions: 

NVH Interface (including BNCs)

 

Microphone

 

Magnet (including grub screw)

105 mm x 65 mm x 27 mm

43 mm x ø17 mm

12 mm x ø18 mm

Sensor extension lead length

3 m

Battery type

CR123(A) 3 V lithium primary cell, 

user-replaceable

Typical battery life: 

Shelf life

 

Vibration mode

 

Microphone mode

10 years

6 months

2 months

Maximum measurable acceleration

g

Output BNCs

0 to 2 V, DC-coupled

Vibration frequency range (–3 dB)

DC to 350 Hz

BNC overvoltage protection

30 V

Accelerometer head shock survivability

10 000 g

Accelerometer head operating temperature range

–40  °C to +85 °C

Accelerometer thread mounting

¼” x 28 UNF

Microphone sensitivity

45 mV/Pa, nominal, at 1 kHz

Approval

CE

Pico Technology, PicoDiagnostics and PicoScope are registered trademarks of Pico 

Technology Ltd. The PicoDiagnostics software is protected by United Kingdom Patent 

GB2442797A “Engine diagnostic system”.
Manufactured in the United Kingdom.

Copyright © 2013-2018 Pico Technology Ltd.

United Kingdom global HQ:
Pico Technology
James House
Colmworth Business Park
ST. NEOTS
PE19 8YP
United Kingdom 

 

+44 (0) 1480 396395

 

+44 (0) 1480 396296

 

[email protected] 

North America regional office:
Pico Technology
320 N Glenwood Blvd
Tyler
Texas 75702
United States
 

 

+1 800 591 2796

 

+1 620 272 0981

 

[email protected]

Germany regional office:
Pico Technology GmbH
Im Rehwinkel 6
30827 Garbsen

Germany

 

+49 (0) 5131 907 6290

 

+49 (0) 5131 907 6297

 

[email protected]

DO347

Reviews: