![Pico Macom PICO-PRO User Manual Download Page 9](http://html.mh-extra.com/html/pico-macom/pico-pro/pico-pro_user-manual_1555185009.webp)
7
Rev. 03/06
Ph: 800-421-6511
www.picomacom.com
Pico-Pro User Manual
PICO-PRO
3.3 SYSTEM
3.3.1 Single Channel Test
Press key “2ndF” and “F/CH” will enter the
following testing mode. The LCD displays:
Press “F l”, “F2”, “F3” or “F4” to switch
between the above 4 test modes.
Press
s
or
t
to change frequency and
channels. Press key pad to easily input
channel number and/or frequency to the
nearest thousands.
3.3.2 Scan Channels
Press “SCAN” to enter Channel SCAN mode.
The LCD displays:
Press key
s
or
t
to change reference level
display at 10dB/Division. Press key “F1” to
change display scale. The value is 10dB or 20
dB/ division. Press key “F4” to change the
scan channel numbers (i.e., the display is
enlarged). Zoom in 1X, 2X, or 4X. Press “F2”
or “F3” to move the marker right or left.
At Channel SCAN mode, press key “2ndF”
plus other second function key to save (“8”)
the tested data, or reload (“9”), or print or
delete saved data.
3.3.3 Spectrum Test
Press key “2ndF” and “SPECT” to enter
SPECTRUM testing mode. The LCD displays:
Press
s
or
t
to change display reference
level at 10 dB/ division.
Press “F1” to change display scale to 10dB or
20dB/division. Press “F2” or “F3” to input cen-
tral frequency (CENT) or scan width (SPAN).
Press “F4” to change 4 keys operation and
enter frequency marker operation. At this
instance press “F1” to automatically move the
frequency marker to the frequency point of the
highest level (Peak). Press key “F2” or “F3” to
move marker right or left.
In spectrum test mode press “2ndF” plus other
second function key to save tested data, load,
print or delete saved data.
Pico Pro Manual 06.qxd 4/10/06 3:20 PM Page 7