Page 1.2
8 TRIBUTARY 75Ω DAISY CHAIN SWITCH 40-792
pickering
SECTION 1 - TECHNICAL SPECIFICATION
pickering
test
.com
Typical RF Performance Plots for 40-793-701
(1 Tributary Switched To The Test Multiplexer)
General Specification (All Versions)
Maximum Voltage:
Maximum Power:
Maximum Switch Current:
100VDC/100VAC
30W
1.0A
On Path Resistance:
Off Path Resistance:
<500m
Ω
>1x10
8
Ω
Expected Life (Low Power):
Expected Life (Max Power):
>1x10
8
operations
>2x10
5
operations
Total Switching Time:
Relay Mechanical Setting Time:
10ms
<3ms
R.F. Specification (Multiplexer)
Characteristic Impedance:
75
Ω
Maximum Frequency:
Rise Time:
Insertion Loss (<10MHz):
Return Loss (<10MHz):
VSWR (<10MHz):
Isolation (<10MHz):
100MHz
<1ns
<0.3dB
>21dB
<1:1.15
>50dB
0dB
-0.2dB
-0.3dB
-0.4dB
-0.5dB
-0.6dB
-0.7dB
-0.1dB
2.5MHz
5MHz
7.5MHz
40-793 INSERTION LOSS
10MHz
1.6
1.4
1.2
1.0
5MHz
40-793 VSWR / RETURN LOSS
1.8
10MHz
13dB
16dB
21dB
11dB
V
S
W
R
Re
tu
rn
L
os
s
26dB
2.5MHz
7.5MHz
-40dB
-50dB
-60dB
-70dB
-80dB
2.5MHz
5MHz
7.5MHz
40-793 CROSSTALK
10MHz
-90dB
All C hannels Terminated into 75ohms
-40dB
-50dB
-60dB
-70dB
-80dB
2.5MHz
5MHz
7.5MHz
40-793 ISOLATION
10MHz
-90dB
All C hannels Terminated into 75ohms
SDH/SONET Tributary Testing is a very specialised
area, please contact Pickering Interfaces for additional
application information and to discuss your exact
requirements.
Pickering Interfaces also have SDH/SONET switching
solutions in our System 30 (VXI) and System 20 (IEEE-
488) switching systems.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com