background image

6

HOW TO SWITCH THE BLOOD GLUCOSE METER ON AND OFF

The glucose meter is switched on by one of the following methods:
 •   Pressing the 

C

 button once;

 •   Pressing the down scroll button (

) once;

 •   Press and hold the up scroll button (

) and the down scroll button (

) at the same time.

 •   Inserting the reactive strip in the test strip slot. 
The glucose meter is switched off by one of the following methods:
 •   Pressing the 

C

 button for 3 seconds;

 •   Automatically after 3 minutes of idle time;
 •   Removing the reactive strip with test strip ejector.

THE FOUR MEASURING MODES

The meter provides you with four modes for measuring, General (no show), AC, PC and QC. You can switch 
between each mode by:
 •    Start with the meter switched off. Insert a test strip to turn on the meter. The screen will display “CHK” and a 

flashing “   ” .

•   Press 

C

 to switch between General (no show), AC, PC and QC mode. 

QUALITY CONTROL TESTING

When Should the Control Solution Test be Performed?

•  if it is mandatory following the local regulations in your country,
•  if you suspect the meter or test strips are not working properly,
•  if your blood glucose test results are not consistent with how you feel, or if you think the results are not accurate,
•  to practice the testing process, or
•  if you have dropped or think you may have damaged the meter.

The items specified below may not be included in the kit (please check the contents on your product box) but 
are required for control solution test or blood glucose test. Please make sure you have those items needed for a 
test beforehand: Test strips 

(c),

 control solutions 

(d)

, lancing device 

(e)

 or sterile lancets 

(f)

. Please contact the 

consumers’ toll-free number for Italy 800 900 080 and for France 01.55.93.26.48. to request the control solution.

Performing a Control Solution Test

To perform a control solution test, you will need: 

(b)

(c) 

and 

(d)

.

1. 

Insert the test strip to turn on the meter

Insert the test strip into the meter. Wait for the meter to display “CHK”,and a flashing “   ”.

2. 

Press C to mark this test as a control solution test

With “

QC

” displayed, the meter will store your test result in memory under “

QC

”. If you press C again, the “

QC

” 

will disappear and this test is no longer a control solution test.

Summary of Contents for GoClic

Page 1: ...Part no 311 0000 000 048 Product name 機器說明書 NO LOGO GoGlic 4218A Pikdare 英文 Spec L148 W105mm 模造紙80P 黑 共 頁 騎馬釘 Writer Lesley Color BLU PANTONE 281C ...

Page 2: ......

Page 3: ...Blood Glucose Monitoring System Owner s Manual TD 4218 ...

Page 4: ......

Page 5: ...agnostic use by people with diabetes at home and by health care professionals in clinical settings as an aid to monitoring the effectiveness of diabetes control It is intended to be used for the quantitative measurement of glucose sugar in fresh capillary whole blood samples from the fingertips and palm and from venous arterial and neonatal blood sample It should not be used for the diagnosis of o...

Page 6: ...es that may cause erroneous results 8 Do NOT use this instrument in close proximity to sources of strong electromagnetic radiation as these may interfere with the accurate operation and inaccurate results could arise 9 Proper maintenance and periodically control solution test are essential to the longevity of your device If you are concerned about your accuracy of measurement please contact the cu...

Page 7: ...erforming a Blood Glucose Test 8 Alternative Site Testing 10 METER MEMORY 10 Reviewing Test Results 10 Reviewing Blood Glucose Day Average Results 11 DOWNLOADING RESULTS ONTO A COMPUTER 11 Data Transmission via Cable 11 BLUETOOTH PAIRING 11 Data Transmission via Bluetooth 11 MAINTENANCE 12 Battery 12 Replacing the Battery 13 Caring for Your Meter 13 Caring for Your Test Strips 14 Caring for Your L...

Page 8: ......

Page 9: ... or continue to get results which are higher or lower than usual follow the treatment advice of your healthcare professional Use only fresh whole blood samples to test your blood glucose Using other substances will lead to incorrect results If you are experiencing symptoms that are inconsistent with your blood glucose test results and you have followed all the instructions given in this owner s ma...

Page 10: ...k Guide 5 Strip Manual 6 Daily Log Book 7 10 Sterile Lancets 5 lancets 30G and 5 lancets 32G 8 Lancing Device for full kit 9 Carry Bag 10 Two AAA Batteries NOTE If any items are missing from your kit or opened prior to use please contact the customers toll free number for Italy 800 900 080 and for France 01 55 93 26 48 ...

Page 11: ...R MEANING Green while the strip is inserted or result in range Red result below the range Orange result above the range or ketone warning 5 Test Strip Slot Insert test strip here to turn the meter on for testing 6 Up Scroll Button Adjust value increment 7 Down Scroll Button Activate the Bluetooth function and adjust value decrement 8 Data port Download test results with a cable connection 9 Batter...

Page 12: ...e 4 Contact Bars ATTENTION The front side of test strip should face up when inserting test strip Test results might be wrong if the contact bar is not fully inserted into the test slot NOTE The GoGlic blood glucose monitoring system shall only be used with GlicTest TD 4340 glucose test strips The GlicTest glucose test strips are preserved completely in their original vial Use each test strip immed...

Page 13: ...n and OFF Press C 6 Deleting the memory With dEL and on the display press to select no to keep the results in memory and then press C To delete all the results press to select yes and then press C to delete all the memory records 7 Setting the reminder alarm Your meter has four reminder alarms The meter will display OFF and AL1 If you don t want to set an alarm press or to select OFF and then pres...

Page 14: ...untry if you suspect the meter or test strips are not working properly if your blood glucose test results are not consistent with how you feel or if you think the results are not accurate to practice the testing process or if you have dropped or think you may have damaged the meter The items specified below may not be included in the kit please check the contents on your product box but are requir...

Page 15: ...on use only It is not a recommended range for your blood glucose level See the MAINTENANCE section for important information about your control solutions Use only GlicSolution TD 4908 and TD 4909 as control solution for your meter TESTING WITH BLOOD SAMPLE WARNING To reduce the chance of infection Never share a lancet or the lancing device Always use a new sterile lancet Lancets are for single use...

Page 16: ...TEST 4 After cocking the lancing device back hold the lancing device firmly against the side of finger and then press the release button DIGITEST DIGITEST 5 In order to decrease the possibility of infection dispose of the used lancets in accordance with local guidelines Each lancet must be used one time only Do not share used lancets with another person Pay attention not to bring the lancet near t...

Page 17: ... sample to the test strip within 3 minutes the meter will automatically turn off You must remove and reinsert the test strip to start a new test The confirmation window should be filled with blood before the meter begins to count down If there is insufficient blood volume in the test strip confirmation window you can apply second drop of blood to the same strip before countdown begins The meter wi...

Page 18: ... NOT use AST if You think your blood glucose is low You are unaware of hypoglycemia You are testing for hyperglycemia Your AST results do not match the way you feel Your routine glucose results often fluctuate METER MEMORY The meter stores the 1000 most recent blood glucose test results along with respective dates and times in its memory To enter the meter memory start with the meter switched off ...

Page 19: ...nd the user manual both free of charge please visit http web picsolution com picglicsoftware html 2 Connecting to a personal computer Connect the cable to a USB port on your computer With the meter switched off connect the other end of the USB cable to the meter data port USb will appear on the meter display indicating that the meter is in communication mode 3 Data transmission To transmit data fo...

Page 20: ... meter shall be on before transmitting data to the Pic Health Station app Bluetooth Indicator on the Meter BLUETOOTH INDICATOR STATUS Flashing Blue The Bluetooth function is on and waiting for connection Solid Blue The Bluetooth connection is established WARNING While the meter is in transmission mode it will be unable to perform a test Make sure your device supports Bluetooth Smart Technology Als...

Page 21: ...y Meter Disposal The used meter should be treated as contaminated that may carry a risk of infection during measurement The batteries in this used meter should be removed and the meter should be disposed of in accordance with local regulations THIS PRODUCT COMPLIES WITH EC DIRECTIVE 2006 66 EC The crossed bin symbol on the batteries or product pack indicates that at the end of their life they must...

Page 22: ...d remaining test strips after 6 months Do not use test strips beyond the expiration date This may cause inaccurate results Do not bend cut or alter a test strip in any way Keep the strip vial away from children since the cap and the test strip may be a choking hazard If swallowed promptly see a doctor for help For further information please refer to the test strip package insert Caring for Your La...

Page 23: ...dual target area SOLID ORANGE Value is above the pre set individual target area SOLID ORANGE If the value is 240 mg dL 13 3 mmol L the value flashes as triangle icon with exclamation mark flashes Ketone Warning This is shown when your blood glucose result is equal to or higher than 240 mg dL 13 3 mmol L What to Do Check blood ketone if checking ketones is part of your diabetes management program N...

Page 24: ... Appears when the batteries are too low Replace the batteries immediately E 2 Appears when a used test strip is inserted Repeat with a new test strip E 3 Appears when test strip is removed while counting down or insufficient blood volume Review the instructions and repeat test with a new strip If the problem persists please contact the Consumers toll free number for Italy 800 900 080 and for Franc...

Page 25: ...rip Sample applied after automatic switch off 3 minutes after last user action Repeat the test with a new test strip Apply sample only when flashing appears on the display Defective meter Please contact Consumers toll free number for Italy 800 900 080 and for France 01 55 93 26 48 3 If the control solution testing result is out of range POSSIBLE CAUSE WHAT TO DO Error in performing the test Read i...

Page 26: ... switch off after 3 minutes without action Temperature Warning Operating Condition 8 C to 45 C 46 4 F to 113 F 10 to 85 R H non condensing Meter Storage Transportation Conditions 25 C to 60 C 13 F to 140 F 10 to 95 R H non condensing Strip Storage Transportation Conditions 2 C to 30 C 35 6 F to 86 F Vial Pack 2 C to 30 C 35 6 F to 86 F Individual Pack 10 to 95 R H non condensing KIT Storage Transp...

Page 27: ... EU the IVD Directive 98 79 EC and the Directive 2011 65 EU RoHS The full text of theEUdeclarationofconformityaccordingtoREDDirective2014 53 EU isavailableatthefollowinginternetaddress http taidoc com download declaration of conformity NOTE The Bluetooth trademark and logos are registered trademarks of SIG Inc and any use thereof by PIKDARE and TAIDOC is under license Google Play and the Google Pl...

Page 28: ...or use Serial number Temperature limit Caution Use by date Humidity limitation Batch code 0123 98 79 EC CE marking according to IVD directive 98 79 EC Authorized representative in the European Community 2014 53 EU CE marking according to RED directive 2014 53 EU Catalogue number Sterilized using irradiation for lancets only ...

Page 29: ...21 NOTE ...

Page 30: ......

Page 31: ......

Page 32: ... TD 4218 Cat No 02058000100000 MedNet GmbH Borkstraβe 10 48163 Mϋnster Germany TaiDoc Technology Corporation B1 7F No 127 Wugong 2nd Rd Wugu Dist 24888 New Taipei City Taiwan www taidoc com Distribuito da Distributed by Distribué par Distribuìdo por PIKDARE S p A Via Saldarini Catelli 10 22070 Casnate con Bernate CO Italy 0123 98 79 EC 2014 53 EU ...

Reviews: