5
SETTING THE METER
Before using your meter for the first time or if you change the meter battery, you should check and update these
settings.
Entering the Setting Mode (a)
Start with the meter off (no test strip inserted). Press and hold
▲
and
▼
at
the same time.
1.
Setting the date
The sequence of the date setting is: YEAR
→
MONTH
→
DAY. With the YEAR / MONTH / DAY flashing in
sequence, press
▲
or
▼
to select the correct number. Press
C
.
2.
Setting the time format
Press
▲
or
▼
to select the desired time format (12h or 24h). Press
C
.
3.
Setting the time
With the HOUR / MINUTE flashing in sequence, press
▲
or
▼
to select the correct number. Press
C
.
4.
Setting the low and high target range for measuring mode
The sequence of the low and high target range setting is: Gen low
→
Gen high
→
AC low
→
AC high
→
PC
low
→
PC high. With the settings mentioned above flashing in sequence, press
▲
or
▼
until the desired target
appears. Press
C
.
Please consult your doctor to determine a target range that works best for you.
5.
Setting the buzzer
With the buzzer displays, press
▲
or
▼
to switch between “On” and “OFF”. Press
C
.
6.
Deleting the memory
With “dEL” and “
” on the display, press
▲
to select “no” to keep the results in memory, and then press
C
. To
delete all the results, press
▲
to select “yes”, and then press
C
to delete all the memory records.
7.
Setting the reminder alarm
Your meter has four reminder alarms. The meter will display “OFF” and “AL1”. If you don’t want to set an
alarm, press
▲
or
▼
to select “OFF”, and then press
C
to skip this step. Or select “On” and press
C
to proceed.
With the hour/minute flashing in sequence, press
▲
or
▼
to select the correct hour/minute. Press
C
and go
to the next alarm setting.
NOTICE:
When the alarm beeps, press
C
to switch it off. Otherwise, it will beep for 2 minutes then switch off.
8.
Setting the Bluetooth function
With the BLE displays, press
▲
or
▼
to switch between “On” and “OFF”. Press
C
NOTICE:
This function is referring to the Bluetooth data transmission. If “On” is selected, your result will be transmitted
automatically right after the test.
After all the settings are finished, the meter will display “OFF” and then switch it off.
Congratulations! You have completed all settings!
NOTE:
•
These parameters can ONLY be changed in the setting mode.
•
If the meter is idle for 3 minutes during the setting mode, it will switch off automatically.
Summary of Contents for GoClic