33
AVM™2
English
TECHNICAL DATA
General electric characteristics
Supply voltage
22–28 VDC (typical 24 VDC)
Maximum ripple
1V
RMS
, 50-60 Hz
Power consumption
Nom. 2.6 W @ 28 VDC (max. 7.5 W)
Maximum load on the outputs
4040404
40
mA (short-circuit protected)
MTBF (electronics)
40,000 hours according to MIL-HDBK-217E
Reversed polarity protection
5 minutes at 23
C [73.4
F]
Valve units
Function on/off
Normally closed (NC/NC 2) or normally open (NO)
Function blow-off
Normaly closed (NC)
LED status indicator, colour
Red
Vacuum switches
Outputs
2 digital, 24V, S1 and S2
Vacuum signal levels
See table in the section “setting of the vacuum-signal level”
Hysteresis
Fixed 7 kPa ±1 kPa [2.1 inHg ±0.3 inHg]
Response time
<10 mS
Maximum overpressure
0.7 MPa [101.5 psi]
LED status indicator, colour
Green
Limit value for air saving function (ES)
Level according to output S2
Other data
Blow-off capacity
Adjustable 0–7.5Nl/s [0-15.9scfm]
Operating temperature
0-50
C [32-122
F]
Materials
Al, PA, NBR, SS, PMMA, ABS
Degree of protection
IP65 [NEMA 4]
Cable (accessory)
2 and 5 m PUR
Humidity
90% RH
Man_0117735_AVM2_rev2.book Page 33 Thursday, March 15, 2012 2:05 PM