CAUTION
Risk of crushing by moving parts!
Risk of minor injuries from crushing between the moving parts of the V-417.216211E1 or the
load and a fixed part or obstacle.
►
Use safeguards to protect limbs areas where they could be caught by moving parts.
►
Observe the safety distances in accordance with DIN EN ISO 13857 when installing
protective structures.
NOTICE
Damage due to collisions!
Collisions can damage the V-417.216211E1, the load to be moved, and the surroundings.
►
Make sure that collisions are not possible between the V-417.216211E1, the load to be
moved, and the surroundings in the motion range of the V-417.216211E1.
►
Do not place any cables or other objects in areas where they could be caught by moving
parts.
NOTICE
Excessively long screws and locating pins
Screws and locating pins that are inserted too deeply can damage the V-417.216211E1.
►
Pay attention to the
depth of the mounting and locating holes (p. 31)
V-417.216211E1.
►
Only use screws and locating pins of the correct length for the respective mounting holes.
Mounting the V-417.216211E1 on a Surface
1. If necessary: Allow access to the mounting holes in the base body of the V-417.216211E1.
Possible measures:
■
Temporary
startup of the positioner (p. 20)
and command the platform to a suitable
position
■
Move the motion platform by hand
2. Align the V-417.216211E1 on the surface so that the corresponding mounting holes in the
V-417.216211E1 and the surface overlap.
3. Insert the screws into all accessible mounting holes and tighten.
4. If necessary: Repeat steps 1 to 3 for all concealed mounting holes.
5. Check that the V-417.216211E1 is affixed firmly to the surface.
6.2
Connecting the V-417.216211E1 to the protective earth conductor
The V-417.216211E1 must be connected to the protective earth conductor via the drive
connector.
It is only necessary to connect the V-417.216211E1's base body to the protective earth
conductor when the following conditions are met:
■
The electronics do not guarantee safe connection of the drive connector to the ground
potential.
6 INSTALLATION
V417M0003EN
‒
11/19/2018
13
M O T I O N | P O S I T I O N I N G