10 Technical Data
N472 Linear Actuator
MP144E
Version: 1.3.0
45
The following graph shows the duty cycle in % depending on the number of steps per second.
Figure 16: Duty cycle in % vs. steps/s (vacuum versions of the N-472)
10.5
Dimensions
Dimensions in mm. Note that a comma is used in the drawings instead of a decimal point.
10.5.1
Models with Turned Cable Exit
INFORMATION
The dimensional drawings in the subsequent sections show the N-472.xxx models with
standard cable exit, but also apply to the N-472.xxxY models with turned cable exit.
Take note: In the case of the N-472.xxxY models, the cable exit is located exactly opposite
to the position shown in the dimensional drawings.