10 Technical Data
44
Version: 1.3.0
MP144E
N472 Linear Actuator
Vacuumcompatible models
Number of steps
per second*
Operating time
Duty cycle (max.) / idle time
2000
60 s (max.)
10 % / 9 min
2000
10 s
10 % / 90 s
1000
120 s (max.)
20 % / 8 min
1000
10 s
20 % / 40 s
≤
200
unlimited
unlimited
* Set via the
Maximum Motor Output
operating parameter
The following graph shows the operating time in seconds depending on the number of steps
per second.
Figure 15: Operating time in s vs. steps/s (vacuum versions of the N-472)