GOH Go To Home Position
Used in: Motion in closed-loop operation (32)
Description:
Moves the specified axis to the zero position.
Long description
GOH{
␣
<AxisID>}
.
,
, and
Servo mode must be switched on for the specified axis (axes)
(closed-loop operation). HID control may not be activated for the
corresponding axis.
Format:
GOH[{␣<AxisID>}]
Arguments:
<AxisID>
Axis ID
If multiple axes are specified in the command, they are moved syn-
chronously.
If no arguments are specified, all axes are moved synchronously.
Troubleshooting:
Illegal axis identifier
Servo mode not active (
responds with the value "0")
HAR? Indicate Hard Stops
Used in: Reference point definition options (40)
Description:
Queries whether the hard stops of the specified axis can be used for
reference moves.
Long description
The E-871.1A1N's firmware uses the Use Hard Stops for Referenc-
ing
parameter (0x7A) to determine whether the hard stops
of the axis can be used for reference moves. Depending on the val-
ue of this parameter, the E-871.1A1N activates or deactivates refer-
ence moves that use the hard stops.
Format:
HAR?[{␣<AxisID>}]
Arguments:
<AxisID>
Axis ID
Response:
{<AxisID>=<uint>
␊
}
<AxisID>
Axis ID
<uint>
Can hard stops of the axis be used for reference
moves? (BOOL)
Troubleshooting:
Illegal axis identifier