4.6 Select A, B, C, D
Via four external data lines, step resolution and current shapes can be set instead of using
the selection switch.
For enabling setting by the inputs, the upper front panel selection switch has to be set to
position
F
.
Programming is indicated in the following table.
4.6.1 Table Step Resolution and Current Shape
How to set step resolution and current shape
External programming:
SELECT inputs
D C B A
RESOLUTION
selection switch
Step resolution and current shape
L
L
L
L
0
Conventional full step
L
L
L
H
1
Conventional half step
L
L
H
L
2
Half step triangular
L
L
H
H
3
1/4 step sine-shaped
L
H
L
L
4
1/5 step sine-shaped
L
H
L
H
5
1/10 step sine-shaped
L
H
H
L
6
1/20 step sine-shaped
L
H
H
H
7
1/4 step triangular
H
L
L
L
8
1/5 step triangular
H
L
L
H
9
1/10 step triangular
H
L
H
L
A
1/20 step triangular
H
L
H
H
B
1/4 step trapezoidal
H
H
L
L
C
1/5 step trapezoidal
H
H
L
H
D
1/10 step trapezoidal
H
H
H
L
E
1/20 step trapezoidal
H
H
H
H
F
External programming
Summary of Contents for SINCOS
Page 1: ...Manual 2066 A006 GB Linear Stepper Motor Power Stage SINCOS...
Page 2: ...phytron Manual 2066 A006 GB SINCOS Linear Stepper Motor Power Stage for Bipolar Control Mode...
Page 10: ...phytron Manual 2066 A006 GB 9 2 2 Pin Assignment Fig 4 Pin assigment of the 32 pole connector...
Page 12: ...phytron Manual 2066 A006 GB 11 Fig 5 Schematic diagram...