WARNING
– Serious injury from electric shock!
If the power stage is not operated with SELV/PELV voltages, the risk of
dangerous voltages may be on the device. Touching these components carrying
high voltages can cause serious injury or death from electric shock:
- Always observe the safety concept SELV / PELV to ensure safe insulation
and separation of low voltage supplies from the mains.
- The MSX
+
must be operated with protective measure in chap. 3.3
WARNING
– Serious injury from electric shock!
During electrical installation cables, connectors, etc. can be live.
- Before starting wiring, make sure that none of the power supplies is
connected to the primary side of the mains supply. Isolate the power
supplies from the mains or remove the appropriate fuses.
- All power stages must be inserted and screwed into the controller or SLS
housing before powering up. If necessary, unoccupied slots must be
covered with front plates. Never operate the equipment when open.
- Do not plug or unplug the power stage while powered.
- Do not plug or unplug the connectors while powered.
- If the equipment has been energised, wait 3 minutes after power off to allow
the capacitors to discharge and ensure that there are no residual charges on
cables, connectors and boards.
ATTENTION
Risk of damage by false motor current setting!
The power stage is set to a defined current on delivery!
- The motor current must be set to the designated value before installation
(see data of the motor).
DANGER - Danger of electric arcing!
During electrical installation the cable, connector or similar may be energised.
- Always switch off the supply voltage before connecting or disconnecting any
wires or connectors at the power stage. Do not unplug the connector while
powered
DANGER - Danger of touch voltages!
During electrical installation the cable, connector or similar may be energised.
- The transformer
must
be constructed with reinforced or double insulation to
avoid dangerous touch voltages (50 V
AC
and 120 V
DC
) in case of isolation
error in the transformer.