CONNECTING YOUR SOLENOID

•  Standard 24VAC Solenoids

•  Simply strip wire jacket back approximately ¼” from end of both wires,  

(if not already done by manufacturer).

•  The controller powers AC solenoids (common solenoids used for lawn irrigation) There is no 

hot or neutral wire.  Tie one wire from all the solenoids together and insert wire into #1 slot of 

solenoid plug (provided by Phytotronics) and the other wires into the #2 through #7 slots and 

tighten down firmly, BY HAND,  with supplied Phytotronics screwdriver.

•  3 Wire 24VAC Solenoids  

•  Attach the 2 power wires just like a 2 wire solenoid into solenoid plug.

•  The 3rd wire is a ground wire. (usually green or green with a yellow stripe) 

ground this wire properly with all local, state, and national codes.

•  120VAC solenoids will not work directly with your

  

Nova.

•  You must use some kind of 24VAC interface between your 

   Nova and 120VAC solenoid. i.e. a 24VAC relay.

NOTE: Any attempt to bypass the 24VAC transformer to power this unit directly from a 120VAC 

power source will damage the controller’s circuitry and render it unfit for use.  Such action will also 

void the Phytotronics warranty! 

NOTE:  Maximum controller output is 1 Amp at one time.  If output is exceded, CR ERR will appear 

on the display.  Turn the unit off, fix the condition and turn back on.  This should clear the error.

FOR ANY TROUBLESHOOTING PLEASE CONTACT PHYTOTRONICS @:

OFFICE: (314) 770-0717 FAX: (314) 506-4587 EMAIL: [email protected]

See Phytotronics.com for information regarding  

loaner units or repair policy

4

Wiring Diagram 

for Terminal Strip

7

6

5

4

3

2

1

C

omm

Z1

Z2

Z3

Z4

Z5

Z6

Summary of Contents for Nova 1626ET

Page 1: ...g Controller INSTRUCTION MANUAL Please read entire Instruction Manual including Limited Warranty before installation 13688 Rider Trail North Earth City MO 63045 314 770 0717 Fax 314 506 4587 2015 Ad Arama NOVA 1626ET Six Zone Misting Controller ...

Page 2: ...N ZONE 3 20 SECONDS OF ON CYCLE 15 12 10 8 6 4 2 60 OFF MINUTES BETWEEN CYCLE 30 20 15 10 6 4 2 ON ZONE 4 20 SECONDS OF ON CYCLE 15 12 10 8 6 4 2 60 OFF MINUTES BETWEEN CYCLE 30 20 15 10 6 4 2 ON ZONE 5 20 SECONDS OF ON CYCLE 15 12 10 8 6 4 2 60 OFF MINUTES BETWEEN CYCLE 30 20 15 10 6 4 2 ON ZONE 6 20 SECONDS OF ON CYCLE 15 12 10 8 6 4 2 60 OFF MINUTES BETWEEN CYCLE 30 20 15 10 6 4 2 ON 8 1 ON Tim...

Page 3: ... Between Cycle The Minutes Between Cycle switch is located at the bottom of each Zone Control Block Rotating the selector switch clockwise will increase the amount of time between the start of each On cycle when 24VAC power is delivered to the appropriate valve Rotating the selector switch counter clockwise will decrease the amount of time The OFF position will prohibit any valve operation while t...

Page 4: ...LER LOCATION Selecting the proper location for mounting your new controller is important and there are several guidelines you should follow to insure long and satisfying service 1 HEAT Avoid locations of excessive heat such as extended exposure to direct sunlight and locations near heaters or boilers 2 LIQUIDS Select a location where the controller is away from direct and continuous flooding from ...

Page 5: ...ltiple times during the night Events cannot control single zones only turn all of of the zones on and off There can be up to 8 events on off functions that can be programmed Press hold the ENTER key for 2 3 Seconds Event 1 will first appear indicating ON Pressing the UP or DOWN key will begin the time setting Press the ENTER key again to program the OFF time and use the UP or DOWN key to set the t...

Page 6: ...properly with all local state and national codes 120VAC solenoids will not work directly with your Nova You must use some kind of 24VAC interface between your Nova and 120VAC solenoid i e a 24VAC relay NOTE Any attempt to bypass the 24VAC transformer to power this unit directly from a 120VAC power source will damage the controller s circuitry and render it unfit for use Such action will also void ...

Page 7: ... Trail North Earth City MO 63045 314 770 0717 Fax 314 506 4587 1 2 3 4 5 6 7 8 Event ON Time AM PM OFF Time AM PM E V E N T P L A N N E R 1 2 3 4 5 6 7 8 Event ON Time AM PM OFF Time AM PM E V E N T P L A N N E R ...

Page 8: ...OR PERFORMANCE OF ANYWARRANTY ORTHE USE OR INABILITYTO USETHIS PRODUCT FOR ANY PURPOSE WHATSOEVER YOUR EXCLUSIVE COMPENSATION FOR LOSS OR DAMAGE ARISING FROM PURCHASE USE REPAIR OF REPLACEMENT OF ANY PRODUCT SHALL BE LIMITED TO AN AMOUNT EQUAL TO THE PURCHASE PRICE OF THE PRODUCT THIS LIMITATION OF LIABILITY SHALL BE APPLICABLE TO ANY CLAIMS PRESENTED TO US REGARDLESS OF THE LEGAL THEORY FORMING T...

Reviews: