Delivery Contents / Technical Data
PHYTEC Messtechnik GmbH 2008 L-720e_0
61
S
ta
rt-
U
p
This prevents, for example, the creation of white images caused by
multiplying pixels.
The normalization factor can be selected from
Options
pull-down
menu
under
Type Casting Settings
(see Figure 33).
Figure 33: Selecting the Normalization Factor
The actual value is displayed in the bottom section of the
Arithmetic
menu.
Caution:
Incorrect settings of the normalization factor will provide
unsatisfactory results with arithmetic operations (i.e black or white
images).
•
The
Add Live Images
option enables up to 1000 consecutive live
images to be compiled into a single image.
•
The desired number of images can be selected under
Options /
Addition Settings
(see Figure 34
).
Figure 34: Number of Images