pciGrabber-4x4
42
PHYTEC Messtechnik GmbH 2008 L-720e_0
Depending on whether decoder is chosen under
Basic Settings
you
must connect the camera to corresponding socket to get an picture.
VD-012 Decoder 1
-> Channel 1 at socket
VD-012 Decoder 2
-> Channel 1 at socket
VD-012 Decoder 3
-> Channel 1 at socket
VD-012 Decoder 4
-> Channel 1 at socket
or
VD-012-X1 Decoder 1
-> MINIDIN at socket
VD-012-X1 Decoder 2
-> MINIDIN at socket
VD-012-X1 Decoder 3
-> MINIDIN at socket
VD-012-X1 Decoder 4
-> MINIDIN at socket
or
VD-012-X2 Decoder 1
-> Channel 1at socket
-> MINIDIN at socket
VD-012-X2 Decoder 2
-> Channel 1 at socket
-> MINIDIN at socket
In the
Color Mode
field, the user can choose to display the image in
color, or in monochrome.
The remaining entries under
Image selection
can retain their
pre-configured values.
Exit the menu by clicking
OK.
Now select the
Live Image
command from the
Image
pull-down
menu
.
A live image from the selected video source will now be displayed in
a new window (see Figure 24
)