Fig.1
Fig.3
SITING:
Avoid positioning above lightly coloured or polished surfaces.
Site carefully to avoid causing obstructions.
INSTALLATION:
Remove the cover assembly using the hex key as shown. (Fig.1) Turn the
2
mounting screws fully
clockwise
then slide the assembly forward in the direction shown. (Fig.2) The cover assembly can
now be removed from its backplate. (Fig.3)
FIXING
Place the hand dryer base at the desired location. Using the backplate as a template, mark the
position of the four fixing holes (Fig.4). Note; a keyhole slot is provided to aid installation.
Drill the wall to accept the plugs and screws provided. Secure the backplate assembly.
POWER CONNECTOR MODULE
The dryer benefits from a quick-connect power supply system which interfaces with the fixed
backplate.
The connector module position is dictated by the backplate. It must be positioned and
secured as shown (Fig.5) to ensure correct cover fitment. Make provision for the electrical supply with
reference to the entry requirement of the power connector module.
POWER CONNECTION MODULE-FITTING
Remove the 2 screws as shown (Fig.6) to release the outer cover.
Remove the terminal connector by sliding upward as shown (Fig.7). This provides access to
securing holes in the module base component.
Position the base component as described previously (Fig.5) and mark the position of the 3
securing holes. Drill the wall to accept the plugs and screws provided. Fix the module base in
position. Ensure that it is secure.(Fig.8)
The hand dryer must be connected to the supply via a fused, double-pole isolating switch having a
contact separation of at least 3mm in all poles.
Feed the supply cable through the entry hole in the module base as shown. (Fig.9). Connect the
supply conductors as follows:
BROWN
wire to the terminal marked
L
BLUE
wire to the terminal marked
N
NOTE: This is a class 2 insulated product and does not require earth bonding. The terminal connector
has the facility to ‘park’ an earth conductor if one is present.
Re-fit the terminal connector. This is the reverse of removal in (Fig.7). Secure the cable beneath
the cable clamp (Fig.10)
Replace the outer cover and secure using the 2 screws removed previously (Fig.11)
COVER RE-FITTING
Installation can now be completed by making the connection to the power module and replacing the
cover assembly.
Locate the power plug situated inside the cover assembly (Fig.12)
Connect to the terminal in the power connection module (Fig.13)
Locate the cover assembly on the backplate and slide downward into position. This is the
reversal of the installation process in Fig’s 1, 2 & 3.
Secure the cover assembly by rotating the
2
mounting screws
anti-clockwise
.
DO NOT OVER
TIGHTEN.
TESTING
Switch on at the supply. The standby light within the cover should illuminate.
Place hands beneath the dryer. The dryer should start automatically and the light indicator will
change from standby to operating mode.
When the hands are removed the dryer should stop within a few seconds and the standby light
should be visible again.
Fig.2
Fig.4
Fig.5
Fig.6
Fig.7
Fig.8
Fig.9
Fig.10
Fig.11
Cable entry options. Either
from rear of backplate or
through cover access knockout.