3.17.5. GENERAL IN Connector
The effect when a signal is input is described below, and can be optionally selected and set.
The input voltage is 0V to +12V (H level +2.5V to +12V), positive or negative polarity, pulse width is
200 ns or greater.
TRIG POS/NEG
Inputs a TTL trigger signal.
READY POS/NEG
Inputs a change recording ready status signal (READY ON/OFF).
•
To make the setting from the menu, refer to “3.20.1. GENERAL IN Signal Settings”, page 63.
•
To make the setting from PFV, refer to "Photron FASTCAM Viewer User’s Manual".
3.17.6. GENERAL OUT (1, 2, 3) Connector
These are also BNC connectors. The signals below can be changed and output from the menu or
PFV.
(POS: positive polarity, NEG: negative)
SYNC POS/NEG
Outputs a vertical synchronization signal.
EXPOSE POS/NEG
Outputs the camera's exposure period signal.
* Outputs during both LIVE and recording.
REC POS/NEG
Outputs a signal during recording.
TRIG POS/NEG
Outputs the trigger signal the camera received.
READY POS/NEG
Outputs a signal that indicates the recording ready state.
•
For details refer to “3.20.2. GENERAL OUT Signal Settings”, page 64.
51
FASTCAM SA-Z Hardware Manual
Summary of Contents for FASTCAM SA-Z
Page 1: ...F FA AS ST TC CA AM M S SA A Z Z...
Page 13: ...Chapter 1 Overview 1 1 Product Overview and Features 1 FASTCAM SA Z Hardware Manual...
Page 65: ...TRIG TTL IN GENERAL TTL IN TRIG SW IN SYNC IN Circuit Diagram 53 FASTCAM SA Z Hardware Manual...
Page 84: ...Chapter 3 Recording 72...
Page 90: ...Chapter 4 Connecting a PC 78...
Page 91: ...Chapter 5 Product Specifications 5 1 Specifications 79 FASTCAM SA X Hardware Manual...
Page 95: ...83 FASTCAM SA Z Hardware Manual...
Page 103: ...91 FASTCAM SA Z Hardware Manual...
Page 115: ...Chapter 6 Warranty 6 1 About the Warranty 103 FASTCAM SA Z Hardware Manual...
Page 117: ...Chapter 7 Contacting Photron 7 1 Contact Information 105 FASTCAM SA Z Hardware Manual...