NOCTURN XS MONO
USER GUIDE
PHOTONIS
USA
Proprietary
and
Confidential
Information
6170
Research
Road
|
Suite
208,
Frisco,
Texas
75033
34
Command
Optional
Payload
Description
off
correction
Disables the non-uniformity offset
correction
global
gain
Displays the global gain for the non-
uniformity correction on the console
global
gain
xxx
Sets global gain for the non-uniformity
correction to xxx
global
offset
Displays the global offset for the non-
uniformity correction on the console
global
offset
xxx
Sets global offset for the non-uniformity
correction to xxx
load
gain
[filename]
Loads gain file [filename] into bufferset
load
offset
[filename]
Loads offset file [filename] into bufferset
status
Displays current status of the non-
uniformity correction on the console
use
bufferset
Displays the current buffer set in use
use
bufferset
xx
Sets bufferset number to xx to use for
gain and offset tables
3.1.3.10
Temperature
Commands
All valid serial command shown in Table 14 should be sent as:
TEMP
<Command>
<Optional
Payload><CR><LF>
Table
14
Temperature
commands
Command
Optional
Payload
Description
?
Temperature help menu
rd
[xx]
Reads temperature sensor register xx (0
is currently the default on the NOCTURN
camera)