1

 
 

 

 

Sealed maintenance-free   

200Ah 12V gel VRLA deep cycle battery 

Model GEL-DC-12V200AH 

 

INSTRUCTION MANUAL 

 

 

 
 
Photonic Universe Ltd   

Tel: +44 (0) 203 150 1111 
Fax: +44 (0) 203 150 1212 
Email: 

[email protected]

 

Website and online shop: 

www.PhotonicUniverse.com

 

 

I. INSTALLATION AND CONNECTION 

 

A) Keep the battery in a cool, dry, ventilated and clean place. 

B) When connecting the wires, screw all the nuts, bolts and washers tightly. 

C) If  you  use  the  battery  within  other  equipment,  keep  it  away  from  a  heat  generating  source  (e.g. 

transformer) and install it as low as possible with proper ventilation. 

D) The battery may produce combustible gas. Avoid installation in a closed compartment or near sparks (e.g. 

near a switch or fuse) 

E) Use well insulated tools when installing the battery. 

F) Avoid using the battery in the following places: 

 

Areas exposed to direct sunlight or any heat source 

 

Areas with radiant heating, infrared radiation or ultraviolet radiation 

 

Areas filled with organic solvent, vapour, dust or corrosive gases and substances 

 

Areas with abnormal vibration or risk of mechanical damage 

G) When  connecting  the  battery  to  a  charger  or  a  load,  keep  the  circuit  switched  OFF  and  connect  the 

battery’s po) terminal to the po) pole of the charger or the load and the battery’s negative(-) 

terminal to the negative(-) pole of the charger or the load. 

H)  Never  use  batteries  with  different  capacities  or  different  performance  characteristics  within  the  same 

battery bank, as well as new and old batteries together. 

I) Do not connect more than 32 batteries in a single string or connect more than 4 strings in parallel. If more 

batteries are needed for series /parallels application as stated above, please contact us. 

J) Ambient working temperature: from -10 ⁰C to +50 ⁰C. 

 

II. CHARGE & DISCHARGE 
 
A) 

CHARGE 

 

For Cycle Use 

(when the battery is used as a regular power source and it’s discharged / charged frequently)

 

Charging voltage (at 25 ⁰C) 

Initial charging current 

Temperature coefficient 

14.1V – 14.4V 

40A max 

-30mV/⁰C 

If the battery is in cycle use, it is important to fully charge it regularly to minimise sulphation that may cause a 

reduction in battery capacity. For best results use an intelligent multi-stage battery charger / charge controller 

and make sure the battery is charged all the way to the final stage. 