To unplug, first turn the power off by the mains and leave to discharge for 10-15 seconds. The plug and 

power cord can then be disconnected. Do not operate if one of the following has occurred:

• The power cord or plug is damaged, cut or frayed.

• Liquid has been spilt in the machine. Or, the unit exposed to any source of water. (including rain) 

• The machine has been dropped or the case had been damaged

• The machine does not operate normally after following the operating instructions

SAFETY GUIDELINES

• Keep the unit, platform and un-cured parts out of the reach of children.

• The unit should be operated on a stable and level surface, preferably away from direct ambient light.

• Do not look directly into the light if they are on (This should not be possible with the safety switch). If you 

have them please wear light blocking goggles. 

DISPOSAL INSTRUCTIONS

Do not throw any electronic device into typical house hold waste when discarding. To minimise pollution and 

to help protect the environment, please recycle this unit or return to Photocentric.

Please note that the latest instructions can always be found on our website:

www.photocentricgroup.com/3d-support

SAFETY INFORMATION

Please  read  the  instructions  carefully.  Keep  this  document  for  future  reference.  Follow  all  warnings/

instructions marked on the product.

•  Cure M+ weighs 20 kg. Make sure you have 2 people to correctly remove the unit from the crate.

•  The dimensions of Cure M+ are 390mm(H)x440mm(D)x440mm(W). Take  care to choose a flat, stable 

work space to accommodate the dimensions.

•  Plug in the power cord first and then attach to the AC power outlet. Or, vice versa, unplug the power 

cord before disconnecting from the printer. 

• Do not operate outdoors without suitable protection

• Do not allow any resin to enter the chassis: clean spillages immediately.

•  Disconnect  the  printer  from  AC  outlet  before  storage  or  when  not  used  for  a  long  period  of  time  or 

inactive for long periods of time. 

•  This unit is connected to the electrical network with an input of 110-240V, 50/60 Hz.

•  Do not allow anything to rest on the power cord. Do not locate this product where people could walk 

on the cord or in a walk-through location.

•  If an extension cord is used with this product, make sure that the total ampere rating of the equipment 

plugged into the extension cord does not exceed the extension cord ampere rating. Also, make sure that 

the total rating of all products plugged into the wall outlet does not exceed the fuse rating.

•  Do not overload a power outlet, strip or receptacle by plugging in too many devices.

•  Use the product only with the supplied power supply cord set.

• In case of malfunction, disconnect the printer immediately from the power network.

• Do not attempt to fix this product by yourself, as opening or removing covers may expose you to potentially 

dangerous voltage points to other risks.

• Refer all repairs to qualified service personnel. Please send an email to your national supplier or contact 

technical service at:

[email protected]

4

Summary of Contents for CURE M+

Page 1: ...THE NEXT GENERATION OF 3D PRINTING IS HERE CURE M USER MANUAL Power on off CAL SET ET2411 DIGITAL TIMER Timer controller OUT1 START STOP OUT2 HOUR MIN Revision 3 18 05 2021...

Page 2: ...Peterborough PE1 5YW UK Tel 44 1733 349937 info photocentric co uk Year of CE Marking 2021 Paul Holt Director Date of Issue 5th January 2021 Place of Issue Peterborough EC DECLARATION OF CONFORMITY CU...

Page 3: ...crate The dimensions of Cure M are 390mm H x440mm D x440mm W Take care to choose a flat stable work space to accommodate the dimensions Plug in the power cord first and then attach to the AC power out...

Page 4: ...PHOTOCENTRIC M USER MANUAL 5...

Page 5: ...ure reference Contents 1 Description of the essential parts of the machine 2 Safety rules 3 Safety devices 4 Environmental protection 5 Intended use 6 Before operating Cure M 7 Starting and stopping y...

Page 6: ...RE M 6 Glass platform 7 Platform stands 8 Internal vents 9 UV Light 1 On Off Switch 2 Temperature adjustment 3 Temperature Display 4 Time adjustment 5 Time display let s get to know it 1 2 3 4 5 8 6 7...

Page 7: ...ation that could lead to severe injury to persons or property Warning Do not touch the interior of the machine with bare hands immediately after a full curing cycle has been completed Danger Never cir...

Page 8: ...the arrows set the desired temperature or time Once the desired temperature and or time are se lected hold the set button until there is a change to the colon display shown Hour Minute The unit will...

Page 9: ...he machine 440 mm or 17 3 Depth of the machine 440 mm or 17 3 Weight of the machine 20 kg or 44 1 lbs Power Supply 220 240 VAC Power consumption 4 9 A Noise 40 Db Control devices Control switches 24 V...

Page 10: ...e pollution and ensure utmost protection of the global environment please recycle or return to Photocentric for recycling 2205 West Parkside Lane Phoenix 85027 AZ USA www photocentricgroup us Cambridg...