The Big program is designed for drying large 

objects that take up most of the drying volume. 

The UV emission is 100% of its power and the 

exposure time is 90 minutes. The temperature 

curve will reach 40 ° C during the program. The 

program starts by clicking on the BIG icon on the 

icon.

The Photocentric Cure M can store 7 personalized 

programs (0-6) within its user interface.

The Custom programs will allow you to save your 

most used polymerization processes without 

having to enter the values into the CURE M each 

time. The Custom program also allows you perform 

the below:

Adjust UV power from 1% up to 100%.

Adjust the exposure time from 1 second to 100 

hours. The temperature from 20 ° C to 60 ° C (which 

will be reached during the program).

The Clear program is designed for drying objects 

produced with transparent and delicate resins. The 

UV emission is reduced to 10% and the exposure 

time is 20 minutes. The program starts by clicking 

on the CLEAR icon.

The program Custom and 

memorization

Program : Basic

Clear Program.

CURE M

Click on Custom and display the program list 

choose the number of the program you want to 

edit and save, once the program has been selected 

click on Set PRG and set the parameters you want 

and return to the program list.

Check that the program shows the values you have 

set by clicking again on the set program and then 

start the program with START.

During the program you can stop it by clicking on 

STOP or put it in PAUSE. At the end of the process 

the display will indicate the process is complete.

Caution:

Only if you return to the program list will yours be 
stored if you select.
Start after changing programs without returning to 
the program list.
It will be valid only for that work cycle and will not be 
stored.

Storing a program

CURE M