background image

2

DMX50/250

1.  Read  these  instructions  before  operating  this 

apparatus.

2.  Keep these instructions for future reference.

3.  Heed all warnings to ensure safe operation.

4.  Follow all instructions provided in this document.

5.  Do not use this apparatus near water or in locations 

where condensation may occur.

6.  Clean only with dry cloth. Do not use aerosol or liquid 

cleaners. Unplug this apparatus before cleaning.

7.  Do not block any of the ventilation openings. Install 

in accordance with the manufacturer’s instructions.

8.  Do not install near any heat sources such as radiators, 

heat registers, stoves, or other apparatus (including 

amplifiers) that produce heat

.

9.  Do not defeat the safety purpose of the polarized or 

grounding-type plug. A polarized plug has two blades 
with one wider than the other. A grounding type plug 
has two blades and a third grounding prong. The wide 
blade or the third prong is provided for your safety. If 
the provided plug does not 

fit

 into your outlet, consult 

an electrician for replacement of the obsolete outlet.

10. Protect  the  power  cord  from  being  walked  on  or 

pinched particularly at plug, convenience receptacles, 
and the point where they exit from the apparatus.

11.  Only use attachments/accessories 

specified

 by the 

manufacturer.

12. Use  only  with  a  cart,  stand,  tripod,  bracket,  or 

table 

specified

  by  the  manufacturer,  or  sold  with 

the  apparatus.  When  a  cart  is  used,  use  caution 
when  moving  the  cart/apparatus 
combination to avoid injury from tip-
over.

13. Unplug this apparatus during lighting 

storms  or  when  unused  for  long 
periods of time.

14. Refer  all  servicing  to 

qualified

  service    personnel. 

Servicing is required when the apparatus has been 
damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects 
have  fallen  into  the  apparatus,  the  apparatus  has 
been exposed to rain or moisture, does not operate 
normally, or has been dropped.

IMPORTANT SAFETY INSTRUCTIONS

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE COVER (OR BACK

)

NO USER SERVICEABLE PARTS INSIDE

REFER SERVICING TO QUALIFIED PERSONNEL

The  lightning  flash  with  arrowhead  symbol,  within  an 
equilateral  triangle,  is  intended  to  alert  the  user  to  the 
presence  of  uninsulated  “dangerous  voltage”  within  the 
product’

s enclosure that may be of sufficient

 

magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is in-
tended to alert the user to the presence of important operat-
ing and maintenance 

(servicing)

 instructions in the literature 

accompanying the appliance.

WARNING: 

To reduce the risk of 

fire

 or electric shock, do 

not expose this apparatus to rain or moisture.

CAUTION: 

Use of controls or adjustments or performance 

of  procedures  other  than  those 

specified

  may  result  in 

hazardous radiation exposure.

The apparatus shall not be exposed to dripping or splashing and that no objects 

filled

 with liquids, such as vases, 

shall be placed on the apparatus. The MAINS plug is used as the disconnect device, the disconnect device shall 
remain readily operable. 

Warning

: the user shall not place this apparatus in the 

confined

 area during the operation so that the mains switch 

can be easily accessible. 

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

Summary of Contents for DMX1501

Page 1: ...DMX15012501 DMX1501 2501 1500 2500 Watt Power Amplifier ENGLISH User s Manual...

Page 2: ...storms or when unused for long periods of time 14 Refer all servicing to quali ed service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or p...

Page 3: ...onic reserves the right to improve or alter any information suppied within this document without prior notice V1 1 APR 12 2006 INTRODUCTION 4 FEATURES 4 INSTALLATION 5 FRONT PANEL DESCRIPTION 6 REAR P...

Page 4: ...ouring bands We know how excited you no doubt are to unpack your amplifier and set it up right now however in order to get the best performance out of your DMX please read this user s manual carefull...

Page 5: ...re the most common cause of inadequate cooling They may result from improper mounting bundles of power cords clogged dust fil ters and closed rack doors Air flows from the rear of the unit to the fron...

Page 6: ...this level will cause the LED to light 3 Peak LEDs When the audio signal drives the amplifier output cir cuit beyond its power capability it will clip The peak limiter detects this and quickly reduce...

Page 7: ...the right to activate the built in limiter on channel 2 move the number 10 DIP switch to the right LOW CUT FILTER DIP switches 2 and 3 can activate a low cut filter on channel 1 DIP switches 8 and 9 c...

Page 8: ...e operation mode as to avoid damaging your amplifier The Number 4 and 5 DIP switches allow users to change between stereo and parallel input modes whereas DIP switch es 6 and 7 are used to activate br...

Page 9: ...ode allows the input of chan nel 1 to feed channel 2 also allowing the channel 1 and 2 outputs to drive their own speakers inde pendently however with the same source To set to parallel mode DIP switc...

Page 10: ...the power The channel 2 gain control should be set to a minimum and a rated load must be used for the higher output power To set bridge mono mode DIP switches 4 5 6 and 7 should all be set to the righ...

Page 11: ...r in stereo or parallel mode should be greater than 2 ohms and in bridge mono mode should be above 4 ohms When in Bridge mode use the center two connectors only 10 Reset Breaker With rated loads and o...

Page 12: ...12 DMX1501 2501 DIMENSIONS All measurements are shown in mm inches...

Page 13: ...ITER 30Hz 50Hz HIGH PASS FILTER DC FAN SPEED 2 THERMAL SENSING CHASSIS GND OVER CURRENT PROTECTION STEP POSITIVE POWER SUPPLY STEP NEGATIVE POWER SUPPLY STEP POSITIVE POWER SUPPLY STEP NEGATIVE POWER...

Page 14: ...istortion Input Sensitivity 8 Ohm 1 23Vrms 4 0dBu Gain Signal Noise 100 dB 20 Hz 20 kHz Low Frequency Filter 30 or 50Hz selectable Controls Indicators Front Panel Power Switch Gain Controls Rear Panel...

Page 15: ...6103 Johns Road 7...

Page 16: ...16 DMX1501 2501...