background image

Copyright © 2019 Phoenix International Systems, Inc. All Rights Reserved 

 
 

 

 

 

 

 
 

VP1-250-eSSD(A/C) 

 
 

Single-Slot 3U Open-VPX 

Rugged NVMe Disk Module 

 

 

 

 

 

USER’S MANUAL 

 

 

 

 

 

 

 

Summary of Contents for VP1-250-eSSD

Page 1: ...Copyright 2019 Phoenix International Systems Inc All Rights Reserved VP1 250 eSSD A C Single Slot 3U Open VPX Rugged NVMe Disk Module USER S MANUAL ...

Page 2: ..._________________________________________________ Warranty and Support _____________________________________________________ Disclaimer The information contained within this document has been carefully checked and is believed to be entirely reliable and consistent with the product that it describes However no responsibility is assumed for inaccuracies Nor does Phoenix International assume any liab...

Page 3: ... the following VITA profile MOD3 PER 1F 16 3 2 3 Handling To prevent damaging the module be aware of the precautions you need to follow when handling or installing the module A discharge of static electricity from a finger or other conductor may damage static sensitive devices This type of damage may reduce the life expectancy of the device To prevent electrostatic damage Avoid hand contact by tra...

Page 4: ...es are not keyed Caution must be used to ensure the module is not inserted into a slot that will cause damage to the module the backplane or any other device attached to the system Guide module keying is available with no key 0 45 90 270 and 315 Considerations for airflow provided to the module are important Ensure that proper airflow is provided to air cooled modules Conduction cooled modules sho...

Page 5: ...REFCLK GND VPX Connector P1 P1 A B C D E F G 1 PETP0 PETN0 GND PERP0 PERN0 GND NC 2 GND PETP1 PETN1 GND PERP1 PERN1 GND 3 PETP2 PETN2 GND PERP2 PERN2 GND NC 4 GND PETP3 PETN3 GND PERP3 PERN3 GND 5 NC NC GND NC NC GND NC 6 GND NC NC GND NC NC GND 7 NC NC GND NC NC GND NC 8 GND NC NC GND NC NC GND 9 NC NC GND NC NC GND NC 10 GND NC NC GND NC NC GND 11 NC NC GND NC NC GND NC 12 GND NC NC GND NC NC GN...

Page 6: ...E18 PETN3 E19 GND E20 PERN3 E21 PERP3 E22 GND E23 NC E24 NC E25 NC Pin J1 1 S1 GND S2 NC S3 NC S4 GND S5 NC S6 NC S7 GND S8 GND S9 NC S10 NC S11 GND S12 NC S13 NC S14 GND S15 NC S16 GND S17 PETP1 S18 PETN1 S19 GND S20 PERN1 S21 PERP1 S22 GND S23 PETP2 S24 PETN2 S25 GND S26 PERN2 S27 PERP2 S28 GND Pin J1 3 P1 NC P2 NC P3 NC P4 GND P5 GND P6 GND P7 NC P8 NC P9 NC P10 NC P11 DRVACT P12 GND P13 12VPRE...

Page 7: ...ST operate in a fully installed Conduction Cooled REDI cover rack Vibration 3 1 GRMS 5 800Hz at 30 min axis Shock 1500G 0 5ms half sine Storage Temperature 55 to 105 C Relative Humidity 5 to 95 percent noncondensing MTBF 24 800 000 Hours 25 C without drive Must use a Solid State drive capable of temperature range and shock and vibration Compliance Specifications The VP1 250 eSSD SATA SAS Drive Mod...

Page 8: ...pared to supply as much detail as you can concerning the nature of the problem and the conditions in which the problem appeared Obtaining an RMA In order to return the product for repair the following steps are necessary 1 Obtain a Return Materials Authorization number RMA from Phoenix International Customer Service 2 Ship the product prepaid to the designated repair point 3 Provide with the produ...

Reviews: