Light Bar = On
The light bar colors and animations will persist while in 

Settings.

3.3.12 Dew Point 

The screen displays the ambient dew point.

3.3.13 Shut Down Sequence 

Press the Set button to adjust the shutdown time in one 

minute increments ranging from 3 – 20 minutes. 
The shutdown time allows the blower to run to remove water 

from the coil and to allow the evaporator to acclimate to the 

ambient conditions.  At the end of the shutdown time the 

unit will automatically purge to remove any remaining water.
The proper shutdown is dependent on conditions.  Increasing 

your shutdown time will help ensure there is no residual 

water in the unit.
***IMPORTANT*** - Unplugging the unit without running 

the shutdown sequence will allow water to remain in the unit 

after use.  If the unit is tilted more than 20 degrees on the 

non-handle side, water may spill out of unit.

3.3.14 Language 

The display will greet the user in order to help them identify 

the language settings for the machine.
Press the Set button to browse available languages.
Press the Next button to confirm selection and advance to 

the next screen. 

 

Light Bar = On
The light bar colors and animations will persist while in 

Settings.

3.3.15 About This Device 

The following information is displayed on the About this 

Device screen:
Device ID
Hardware Version
Firmware Version
Press the Next button to advance to the next screen. 

 

Light Bar = On
The light bar colors and animations will persist while in 

Settings.

3.3.16 Diagnostic Mode 

Press the Next button for 3 seconds to enter Diagnostic 

Mode. This action can also be performed at any time while 

the machine is powered on.
If Alerts are active, press the Next button to advance to 

the next screen. Else, press the Next button to return to the 

Dashboard. 

 

Light Bar = On
The light bar colors and animations will persist while in 

Settings.

3.3.17 Diagnostic Mode - Pump 

Press the Set button to toggle the Pump On/Off.
Press the Next button to advance to the next screen.

Summary of Contents for Therma-Stor DryMAX 4036150

Page 1: ...asy to determine power to the unit The Phoenix DryMAX is 6 smaller than the closest dehumidifier and yet it still has an integrated handle and wheels as well as onboard storage for the power cord and condensate hose The all new Phoenix Micro Channel condenser allows us to pack so much performance into such a small dehumidifier The feedback on the stacking of the AirMax was so positive we made sure...

Page 2: ...ng The Phoenix DryMAX features a high impact roto molded housing which protects the unit It is recommended the units are properly secured for transport The Phoenix DryMAX must always be on its base when transported by vehicle It may be tipped upright to utilize its handle and back for loading and moving by hand Read the operation and maintenance instructions carefully before using this unit Proper...

Page 3: ...the key to scroll through available values 3 3 4 Purging Press the button to purge the machine The display will communicate to the user that the machine is purging on the fourth line of the dashboard and show a 20 second countdown timer This will momentarily replace grain depression until the machine has finished purging The display will also communicate to the user that the machine is auto purgin...

Page 4: ... to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 9 Humidistat Fan Mode Press the Set button to toggle the Humidistat Fan mode from Always On to Auto Press the Next button to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 10 Hu...

Page 5: ...out of unit 3 3 14 Language The display will greet the user in order to help them identify the language settings for the machine Press the Set button to browse available languages Press the Next button to confirm selection and advance to the next screen Light Bar On The light bar colors and animations will persist while in Settings 3 3 15 About This Device The following information is displayed on...

Page 6: ...gnostic Mode Refrig Test The display will communicate to the user the following information during a Refrigeration Test Inlet Temperature and RH Grains Outlet Temperature and RH Grains Hours Life hours only Evaporator Coil Temperature Countdown timer 20 minutes Once the 20 minute countdown timer has expired the display will automatically advance to show the refrigeration test results The display w...

Page 7: ...urn the dehumidifier on The unit will begin the Powering Up sequence and you will see this screen Press and hold the button to turn the dehumidifier off The dehumidifier will go through a powering down cycle The default shut down time is three minutes plus 20 seconds for a final purge The shutdown time can be changed be scrolling through the menu to this screen IMPORTANT Unplugging the unit withou...

Page 8: ...ystem similar to an air conditioner s to remove moisture from incoming air and to add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coil The refrigerant is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tub...

Page 9: ...top To replace the thermistor probe 1 Unplug the dehumidifier 2 Remove the top housing 3 Pull thermistor probe up and out of evaporator coil 4 Remove control board cover 5 Unthread thermistor probe wire from harness 6 Unplug thermistor probe connector on control board 7 Reassemble thermistor probe and dehumidifier using the above procedure in reverse 5 5 Condensate Pump The internal condensate pum...

Page 10: ... RED 3 YEL 2 BRN 9 BLK 11 BRN BLK BLK 13 BLK 5 BLK BLOWER BLU GRN BLK 4 BLK 13 BLK 5 RH IN RH OUT AUX EVAP FLOAT TEMP RH SENSOR TEMP RH SENSOR PRESS SWITCH THERMISTOR PROBE 1 2 3 4 5 6 LINE NEU WHT 10 WHT 6 WHT 12 WHT 6 WHT 10 WHT FLOAT SWITCH PUMP BLK CORD WHT CORD P N 4036955 CONTROL BOARD POWER BOARD COMPRESSOR CAPACITOR ...

Page 11: ...036943 Handle Bushing RH 4037847 Handle Bracket RH 4024916 Condensate Hose 4036942 Handle Weldment 4036944 Handle Bushing LH 4037848 Handle Bracket LH 4036927 Filter Support 4038477 Filter 4036962 01 Upper Housing Red 4036962 02 Upper Housing Blue Granite 4036961 01 Lower Housing Black 4038478 Impeller 4036928 Exhaust Grill 4037048 Duct Ring 4036935 Rubber Wheel 4036936 Wheel Axle Not Pictured 403...

Page 12: ...ot cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix DryMAX Dehumidifier part is repaired or replaced the new part shall be warranted for only the rema...

Reviews: