The cabinet is equipped with a power supply cable having the following specifications: 

Length 

: 8 FT 

Size 

: 18 AWG 

The  cabinet  shall  be  connected  to  a  dedicated,  grounded  circuit,  protected  by  ON/OFF 

button.  All wiring shall be in accordance with local codes. 

Important:

 

The power supply cable conductors are color-coded as follows: 

GREEN or GREEN/YELLOW 

: GROUND

 

WHITE or BLUE/BLACK 

: NEUTRAL

 

BLACK or BROWN/RED 

: LINE 

 

Service safety rules: 

 

Prior  to  performing  any  maintenance  or  inspection  of  the  CAC  disconnect  the 

power  plug  from  the  electrical  outlet  in  order  to  ensure  that  the  CAC  start 

unexpectedly. 

 

To prevent injuries to person ensure that all removable panels are in place and 

properly secured except for any necessary inspections or maintenance. 

 

The Color assess cabinet shall be installed in an environment conforming to the 

appropriate  local  regulations.  A  permit  issued  by  the  local  authority  may  be 

required.    

 

Do not store flammable materials or other materials inside the cabinet. The area 

in which the Color assess cabinet is installed must be kept free of exposed flames. 

 

It  is  recommended  that  a  ventilation  system,  guaranteed  to  maintain  the 

concentration  of  dangerous  vapors  around  electrical  components  at  less  than 

30%, be installed. 

 

When the Color assess cabinet is not being used for a period of time (such as at 

the  end  of  the  work  day),  ensure  that  it  is  empty  (no  shade  cards  inside  the 

cabinet) turn off the main switch. 

 

Ensure that all cards are removed from inside the cabinet after any maintenance 

work. 

 

RESIDUAL RISK 

Residual risks list for the user: 

The  Color  assess  cabinet  and  its  operating  and  service  instructions  have  been 

developed  giving  careful  consideration  to  the  safety  of  the  user  and  service 

technician.   However, there are situations where risks  can  be reduced  but not 

eliminated completely. 

 

RISK 

PRECAUTION 

Color spill inside the Color assess 

cabinet 

Thoroughly clean the operator and maintenance areas.  

Keep these areas clean. 

 

Summary of Contents for CAC3

Page 1: ...Ver Phoenix 1 0 _ 01 01 2019 1 Phoenix Mixer India Pvt Ltd CAC3 COLOR ASSESS CABINET OPERATING AND SERVICE MANUAL 2008 Phoenix Mixer India Pvt Ltd ...

Page 2: ...ess otherwise indicated all references to companies names data and addresses used in the screens and or examples are purely coincidental and serve only to clarify the use of the Phoenix Mixer Phoenix shall not be liable for technical or editorial errors or omissions made herein nor for incidental or consequential damages resulting from the performance or use of this material If you require additio...

Page 3: ...ETY SPECIFICATIONS 9 6 INSTALLATION 12 7 CONTROLS 13 8 OPERATING CONDITIONS 14 8 1 TEST YOUR EYES FIRST 8 2 CHOOSE LIGHTING CONDITIONS CAREFULLY 8 3DE CLUTTER YOUR SPACE 8 4 SAMPLE ARRANGEMENT 9 SOP OF COLOR ASSESS CABINE 15 10 PREVENTIVE MAINTANCE 16 10 1 USE OF PLATFORM 10 2 Lights HANDLING 11 MAINTANCE AND TROUBLE SHOOTING 17 12 SCHEMETIC DIAGRAM 18 ...

Page 4: ...to this circuit This product is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Removal of the plug from the outlet is the means for isolating the color assess cabinet from the power supply Ensure that the color assess cabinet is installe...

Page 5: ... demands of the lab retail market The dimension of the cabinet makes it versatile and suitable for use in all environments The unique design results in reduced maintenance and in color shade checking at the lowest cost CAC is reliable equipment which performance and design exhibits the qualities of a strong and sturdy engineering product and zero maintenance Phoenix shall not be liable for any dam...

Page 6: ...ckground for natural color Better color evaluation of samples with consistent lighting from 3 light sources Dedicated D65 Light source for Industrial application Easy installation of replacement lamps on your own Three different buttons for light Options of 3 light sources including 65 Artificial day light UV Ultraviolet black light A Tungsten Filament Input Voltage 220 240Vac 50 Hz Interior Color...

Page 7: ...arts of control Systems Part 1 General principles for design EN 1088 1995 Safety of machinery Interlocking devices associated with guards EN 294 1992 Safety of machinery Safety distances to prevent danger zones being reached by the upper limbs EN 953 1997 Safety of machines Guards General requirements for the design and construction of fixed and movable for coating materials PrEN 12757 1 Mixing ma...

Page 8: ...aterial damage are excluded if attributable to one or more of the following causes Or abnormal conditions of operation repairs will be billed at a normal cost In this case an estimate will be submitted before works is started if requested Always include serial number in any correspondence concerning the part unit The warranty expires Twelve month after date of invoicing Operations of the color ass...

Page 9: ...t in dangerous situations or accidents Risk to person is possible in two areas Operator area Maintenance area Maintenance area Operator area THIS EQUIPMENT MUST BE GROUNDED Attention Connect this product to a dedicated electrical circuit no other devices shall be connected to this circuit Do not use extension cords to connect this product Attention Only trained person shall be permitted access to ...

Page 10: ...regulations A permit issued by the local authority may be required Do not store flammable materials or other materials inside the cabinet The area in which the Color assess cabinet is installed must be kept free of exposed flames It is recommended that a ventilation system guaranteed to maintain the concentration of dangerous vapors around electrical components at less than 30 be installed When th...

Page 11: ...rotective equipment safety glasses safety shoes with non slip soles and gloves in particular when loading and unloading the cabinet General danger situations There are no specifically identified hazard related to the operation and maintenance of the Color assess cabinet e g fire risk issue or dispersion of dangerous products However it is recommended that a powder type fire extinguisher suitable f...

Page 12: ...h the unit 230 VAC 50 Hz single phase Select the position of three light switch as follows INSTALLATION It is recommended that during the installation of the Color assess cabinet protective gloves be worn in order to prevent hand injuries Unpack the Color assess cabinet Ensure the cabinet has not been damaged in any way Position the Color assess cabinet in the desired location Ensuring that all fo...

Page 13: ...Ver Phoenix 1 0 _ 01 01 2019 13 Phoenix Mixer India Pvt Ltd 7 CONTROLS Main Display ...

Page 14: ... which you will need to evaluate shade card as specified by customer and by the appropriate viewing lights 8 3 De clutter your space Your CAC should be completely free and clear of any items that aren t being evaluated for color Anything within the range of vision can influence the color of the product and distort your analysis 8 4 Sample arrangement samples are most properly viewed at 0 45 angle ...

Page 15: ... 4000 After 10 Sec blinking will stop Press button D65 A UV To start ON OFF the light Long press of I O Shows System off RESET HOURS Press I O button to System Off 3 Sec Press ESC button to reset 3 Sec After press desired button to be press one time for reset For another tube will reset in system off mode Press ESC Button 3 sec When reset will complete Press I O button for 3 Sec for System ON ...

Page 16: ...cabinet must be rest on feasible table platform which can be operated easily by the person working on it 10 2Lights Handling Always use care and allow cabinet lights to cool first before handling Always use lens paper or an equivalent when picking up and replacing lights as skin oils can interfere with lamp performance ...

Page 17: ...d then and there to avoid difficulties after it gets dried up Gently press the button on panel keep the cabinet clean Troubleshooting PROBLEM TROUBLE SHOOTING Cabinet is not turning ON or Not working 1 Check the Mains supply 2 Check MCB Position it should be ON 3 Check the Power supply 4 Check plug or loose wire Lights are not turning ON even if display is ON 1 Check light fitment in Socket 2 Chec...

Page 18: ...Ver Phoenix 1 0 _ 01 01 2019 18 Phoenix Mixer India Pvt Ltd 12 SCHEMATIC DIAGRAM ...

Page 19: ...9 Phoenix Mixer India Pvt Ltd THANK YOU Phoenix Mixer India Pvt Ltd Plot No 7 Collage Road Vadkun Dahanu Road 401602 Dist Palghar Maharashtra INDIA Phone 91 2528 221120 223324 www phoenixmixer com An ISO 9001 2015 Certified Company ...

Reviews: