![Phoenix 4031350 Owner'S Manual Download Page 5](http://html1.mh-extra.com/html/phoenix/4031350/4031350_owners-manual_1551144005.webp)
www.UsePhoenix.com • [email protected]
Toll-Free 1-800-533-7533
If the airflow is still too low, the HEPA filter must be changed.
To remove the HEPA filter, follow these steps:
1. Loosen the eight screws
one revolution
2. Rotate all eight clips out of
the way.
3. Remove old filter.
4. Installing the new filter
is the reverse of these
instructions
4.2B Optional Activated Carbon/Potassium
Permanganate Filters
Optional gas phase filters are available from Therma-
Stor. They use a blend of activated carbon and potassium
permanganate. This blend removes the vast majority
of gaseous contaminants encountered in most filtering
applications. The activated carbon removes the heavier
volatile organics while the potassium permanganate removes
lower molecular weight contaminants. This is well suited to
the smoke odors present after fire damage.
The life of the media blend depends upon both the hours
used and the contamination level. Another advantage of
the blended media
versus activated
carbon only is that
part of the blend
changes color as
it loads up with
contaminants. It
starts out black,
then turns pink,
then brown, and
finally white. It is
best changed when
it passes the brown
stage and begins
to turn white. It
has lost most of its
effectiveness at that point.
The filter is the same size as the pleated fabric filter. Install it
in place of the pleated fabric filter.
5 Service
CAUTION: Servicing the Phoenix Guardian R HEPA System
with its high voltage circuitry presents a health hazard that
could result in death, serious bodily injury, and/or property
damage. Disconnect the appliance from the power supply
before servicing. Only qualified service people should
service this unit.
5.1 Warranty
A warranty certificate has been enclosed with this unit.
Read it before any repair is initiated. If a warranty repair
is required, call the factory first at 1-800-533-7533 for
warranty claim authorization and technical assistance.
The photo depicts clip in a locked
position. Turn screw counter-clockwise
to remove.
PN 4031350 is pictured
to demonstrate maximum
stackability.