![Phoenix 4031350 Owner'S Manual Download Page 2](http://html1.mh-extra.com/html/phoenix/4031350/4031350_owners-manual_1551144002.webp)
2
www.UsePhoenix.com • [email protected]
Toll-Free 1-800-533-7533
Table of Contents
Introduction
.............................................................................1
1. Specifications
..................................................................2
2. Important Safety Instructions
........................................2
3. Operation
.........................................................................2
3.1 Transporting the Phoenix Guardian R ......................2
3.2 Electrical Requirements ............................................2
3.3 Air Ducting .................................................................3
3.3A Inlet Ducting ......................................................3
3.3B Outlet Ducting ...................................................3
3.3C Negative Air Ducting .........................................3
3.4 Power/Speed Control ................................................3
3.5 Resettable Circuit Breaker ........................................4
3.6 GFCI Protection and On-Board Duplex VAC Outlet...4
3.7 Servicing ....................................................................4
4. Maintenance
....................................................................4
4.1 Air Filters ....................................................................4
4.2 Filter Replacement ....................................................4
4.2A Filter change light..............................................4
4.2B Optional Activated Carbon/Potassium
Permanganate filters .................................................5
5. Service
..............................................................................5
5.1 Warranty .....................................................................5
6. Wiring Diagram
...............................................................6
7. Service Parts
....................................................................7
Warranty
...........................................................................9
Serial No.__________________________________
Purchase Date_____________________________
Dealer’s Name_____________________________
Read the operation and maintenance instructions carefully
before using this unit. Proper adherence to these instructions
is essential to obtain maximum benefit from your Phoenix
Guardian R HEPA System.
1 Specifications
Part No.
4031350 (Red)
4031460 (Blue)
Power
110-120 Vac, 2.4 amps
Blower
500 CFM
Filters:
1st stage 1”Pleated Media, 18” x 18”
(optional) 1” Carbon and Potassium
Permanganate
2nd stage 2.5” Pleated HEPA 18” x 18”
Warranty
One Year, 100% Parts and Labor
Dimensions
Width 22”
Height
14”
Depth
24”
Weight
33 lbs.
2 Important Safety Instructions
CAUTION: Risk of electric shock. Can cause injury or death.
To reduce the risk of electric shock:
• Do not expose to standing water or rain
• Connect to GFCI outlet
• Do not use an extension cord
• Unplug fan before servicing or changing filters.
• Do not block air intake or outlet. One foot minimum
distance to obstructions.
Indoor use only
• Do not use as stool or bench
• Do not operate with damaged cord or plug.
• Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route
cord under furniture or appliances. Arrange cord away
from traffic area and where it will not be tripped over.”
3 Operation
3.1 Transporting the Phoenix Guardian R
The Guardian R should be transported vertically or
horizontally on the appropriate feet located on the
bottom of the unit or opposite the handle
3.2 Electrical Requirements
The Phoenix Guardian R HEPA System can be plugged into a
grounded 15 Amp circuit. It draws about 2.4 Amps with clean
filters and no ducting. The amp draw will decrease slightly
with added ducting and as the filters load with particulate.
Due to the presence of GFCI receptacle, the unit must be
plugged directly into a wall outlet. No extension cords should
be used.