1 Intended Application

The Solution is a specially designed intercooling head that 
provides pre-cooling to the dehumidifier’s incoming air 
stream. Just like the pre-cooling feature is the key to the 
performance leap of LGR dehumidifiers, the Solution can 
actually double the water removal rate of your LGR in some 
conditions.
The enhanced efficiency achieved with the Solution 
practically matches the 1.6 amps required to operate the 
unit, resulting in a minimal overall power increase.

2 Specifications

Model:

 Phoenix Solution (P/N 4026600)

Electrical:

 110-120 Vac, 1.6 Amps, grounded

Operating CFM & Temperature Range:

 

Primary air stream 300 CFM & 33°F min., 125°F max.
Secondary air stream 230 CFM & 15°F min., 125°F max.

Duct Connections:

 4” x 10” rectangular exhaust

 

               8” round intake

Size:

 19” high x 19-1/2” wide x 19-1/2” deep

Weight:

 40 lbs

3 Operation

3.1 Transporting

The Phoenix Solution is designed to be carried by the 
recessed handles built into the front and rear of the unit. 
Multiple Solutions may be stacked for transport on a 
suitable cart. Transporting the Phoenix Solution as it is 
attached to a dehumidifier is NOT RECOMMENDED.

3.2 Installation

The top of the Phoenix Solution is designed to accept the 
filter and top cover from the Phoenix 200 MAX or Phoenix 
200 HT that it is mounted on. The Phoenix Solution is 
designed to engage the spring clips found on the Phoenix 
200 MAX and 200 HT dehumidifiers. An additional bracket 
with engaging tabs (1 included) must be installed on the 
dehumidifier to secure the front of the Phoenix Solution  
chassis.

Read the operation and maintenance instructions 
carefully before using this unit. Proper adherence to 
these instructions is essential to obtain maximum 
benefit from your Phoenix Solution performance 
amplifier.  

•  It is designed to be used 

INDOORS ONLY

.

•  If used in a wet area, plug it into a 

GROUND FAULT 

INTERRUPTER

.

•  

DO NOT

 use the Phoenix Solution as a bench or table.

•  It must always be used in the upright position.
•  The included bracket with engaging tabs must be 

installed correctly on the dehumidifier that the 
Phoenix Solution is attached to.

•  The Phoenix Solution must be removed from the  

dehumidifier for transport to and from the job site.

•  Automatically operated device.
•  Risk of electric shock.
•  Can cause injury or death:  disconnect all remote 

electric power supplies before servicing.

Table of Contents

Introduction

  ...............................................................1

1.  Intended Application

 ..............................................2

2.  Specifications

 ........................................................2

3.  Set Up

 ..................................................................2

 

 3.1 Transporting ...................................................2

 

 3.2 Installation .....................................................2

 

 3.3 Ducting ..........................................................3

 

 3.4 Condensate Removal ......................................3

 

 3.5 Electrical Requirements ...................................4

 

 3.6 Control Switch ................................................4

4.   Maintenance

 .........................................................4

5.   Service

 .................................................................4

 

 5.1 Technical Description ......................................4

 

 5.2 Troubleshooting ..............................................4

 

 5.3 Blower Replacement .......................................4

 

 5.4 Thermostat & Switch Replacement ...................4

6.   Options & Accessories

 ...........................................4

7.   Wiring Diagram

 .....................................................5

8.  Installation Diagram

 ..............................................6

9.  Service Parts

 ........................................................7

 

Warranty

 ...............................................................9

Summary of Contents for 4026600

Page 1: ...er drying times using the Solution by utilizing cold outside air The Solution improves the grain depression of the dehumidified air This increases the vapor pressure differential the key to evaporatio...

Page 2: ...00 HT that it is mounted on The Phoenix Solution is designed to engage the spring clips found on the Phoenix 200 MAX and 200 HT dehumidifiers An additional bracket with engaging tabs 1 included must b...

Page 3: ...ations where the temperature of the secondary air stream is significantly below the dew point of the primary air stream condensation may occur inside the Solution s heat exchanger A drip pan underneat...

Page 4: ...midifier The thermostat is set to turn the impeller on when the process air temperature increases to 80 F The thermostat will turn the impeller off when the process air cools to 70 F Alternatively the...

Page 5: ...5 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 7 Wiring Diagram...

Page 6: ...moval The Solution is a specially designed intercooling head that provides pre cooling to the dehumidifier s incoming air stream Just like the pre cooling feature is the key to the performance leap of...

Page 7: ...Clamp 1 1979212 7 8 Mounting Screw 1 1027265 8 2 to 1 Terminal Adapter 1 4026414 9 Tubular Handle 1 4026399 Item Description Qty Part Number 10 Feet 4 4024073 11 Duct Wire 1 4024078 12 Blower Screen...

Page 8: ...8 www UsePhoenix com sales UsePhoenix com Toll Free 1 800 533 7533 This page intentionally left blank...

Page 9: ...stallation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix Solution LGR Amplifier part is repaired or replaced the new p...

Reviews: