Phoenix 200 MAX Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC 

4201 Lien Rd 

Madison, WI 53704 

Telephone: 1-800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix 200 MAX dehumidifier, 

and may not be assigned or transferred.

First Year Warranty:

 Therma-Stor LLC warrants that, for one (1) year the Phoenix 200 MAX dehumidifier 

will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, 

repair or replace the defective part(s), free of any charge.

Second Through Fifth Year Warranty

: Therma-Stor LLC further warrants that for a period of five (5) years, 

the condenser, evaporator, and compressor of the Phoenix 200 MAX dehumidifier will operate free of any 

defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the defective 

part(s), provided that all labor and transportation charges for the part(s) shall be borne by the end-user.

End-User Responsibilities:

 Warranty service must be performed by a Servicer authorized by Therma-Stor 

LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should 

call Therma-Stor LLC at the above number and ask for the Therma-Stor Service Department., which will 

then arrange for covered warranty service. Warranty service will be performed during normal working 

hours.

The end-user must present proof of purchase (lease) upon request, by use of the warranty card or other 

reasonable and reliable means. The end-user is responsible for normal care. This warranty does not 

cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, 

tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any 

other cause beyond Therma-Stor LLC’ reasonable control.

Limitations and Exclusions

: If any Phoenix 200 MAX Dehumidifier part is repaired or replaced, the new 

part shall be warranted for only the remainder of the original warranty period applicable thereto (but all 

warranty periods will be extended by the period of time, if any, that the Phoenix 200 MAX Dehumidifier is 

out of service while awaiting covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX 200 MAX 

DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES 

MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST 

THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA-STOR LLC, IN 

CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY PHOENIX 200 MAX 

DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT 

OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER 

SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO 

ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the 

exclusion or limitation of incidental or consequential damages, so one or both of these limitation may not 

apply to you.

Legal Rights:

 This warranty gives you specific legal rights, and you may also have other rights which vary 

from state to state.

Summary of Contents for 200 MAX

Page 1: ...rying areas to much lower humidity levels than conventional dehumidifiers The Phoenix 200 MAX an improved version of the original Phoenix 200 is the culmination of over a decade of LGR manufacturing and design expertise The Phoenix 200 MAX LGR High Capacity Dehumidifier Improved water removal 16 gals day 128 pints AHAM 80ºF 60 30 gals day maximum Improved grain depression The driest air from an LG...

Page 2: ... GROUND FAULT INTERRUPTER DO NOT use the Phoenix 200 MAX as a bench or table It must always be used in the upright position Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix 200 MAX dehumidifier Table of Contents Introduction 1 1 Specifications 2 2 Operation 2 2 1 Transpor...

Page 3: ...ditions until the switch is turned off there is no dehumidistat If the unit is going to run for more than 2 hours in an area below 50 F the defrost timer should be adjusted to improve performance see Sec 2 9 2 7 Pump Purge Switch This switch left of hour meter minimizes the water left in the condensate pump reservoir for moving or storage Pressing and holding the pump purge switch will cause the c...

Page 4: ...a drain 2 Plug in the unit but do not turn it on 3 Remove the air filter Slowly pour a quart of the chemical through the heat exchanger 4 Hold in the pump purge switch to reduce the water level in the reservoir 5 Flush with water 4 Service CAUTION Servicing the Phoenix 200 MAX with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death ...

Page 5: ...ive blower Sec 4 5 Unit removes some water but not as much as expected 1 Air temperature and or humidity have dropped 2 Humidity meter and or thermometer used are out of calibration 3 Unit has entered defrost cycle Sec 2 9 4 7 4 Air filter dirty Sec 3 1 5 Defective defrost thermostat Sec 4 7 6 Low refrigerant charge Sec 4 4 7 Air leak such as loose front cover 8 Defective compressor Sec 4 6 9 Rest...

Page 6: ... replaced if continuity exists across its terminals If there is no needle movement with the meter set on the Rx100000 scale the capacitor is open and must be replaced 10 Reconnect the wires to the compressor and capacitor plug in and turn on the unit If the compressor fails to start replace the run capacitor 11 If the unit still does not start adding a hard start kit will provide greater starting ...

Page 7: ...ormation on the evaporator coil the thermostat opens The compressor is then cycled off and on by the defrost timer The blower will continue to run causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increase the evaporator temperature will rise and the thermostat will close to end the defrost cycle 4 8 Condensate Pump...

Page 8: ... of 200 MAX 6 Wiring Diagram 5 Options and Accessories 4021475 16 x 20 x 2 Pleated Media 65 MERV 11 Standardl 4022489 4 Mini Pleat Media 95 MERV 14 Optional 4024750 12 x 25 Intake Flex Duct 4024935 10 x 250 Lay flat Duct 4026600 Phoenix Solution LGR Performance Amplifier 4026734 Phoenix Shield Kit ...

Page 9: ...918 1 Instruction Label 15 4029508 1 Low Pressure Control 16 4021796 1 Pump Purge Switch Item Part No Qty Description 17 4021822 1 Power Switch 18 4029266 1 Top 19 1 Wheel Axle Assembly 4026304 2 Wheel 12 4027125 1 Axle 1284404 2 Cotter Pin 20 4024078 1 Wire Duct Collar Exhaust 21 4025043 1 Skid Panel Items listed below are not shown 22 4023649 1 Condensate Pump 23 4028226 1 Condenser Coil 24 4024...

Page 10: ...e for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Phoenix 200 MAX Dehumidifier part is repaired or replaced the new par...

Reviews: