background image

Phoenix 200 HT Dehumidifier Limited Warranty

Warrantor:

Therma-Stor LLC 
PO Box 8680 
Madison, WI 53708 
Telephone: -800-533-7533

Who Is Covered:

 This warranty extends only to the original end-user of the Phoenix 200 HT 

dehumidifier, and may not be assigned or transferred.

Year One:

 Therma-Stor LLC warrants that, for one () year the Phoenix 200 HT dehumidifier will 

operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, 
repair or replace the defective part(s), free of any charge.

Years Two Through Five:

 Therma-Stor LLC further warrants that for a period of five (5) years, the 

condenser, evaporator, and compressor of the Phoenix 200 HT dehumidifier will operate free of 
any defects in material or workmanship, or Therma-Stor LLC, at its option, will repair or replace the 
defective part(s), provided that all labor and transportation charges for the part(s) shall be borne by 
the end-user.

End-User Responsibilities:

 Warranty service must be performed by a Servicer authorized by 

Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized 
Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor 
Service Department, which will then arrange for covered warranty service. Warranty service will be 
performed during normal working hours.
The end-user must present proof of purchase (lease) upon request, by use of the warranty card or 
other reasonable and reliable means. The enduser is responsible for normal care. This warranty 
does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, 
corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, 
accident, acts of nature or any other cause beyond Therma-Stor LLC’s reasonable control.

Limitation and Exclusions:

 If any Phoenix 200 HT Dehumidifier part is repaired or replaced, the new 

part shall be warranted for only the remainder of the original warranty period applicable thereto 
(but all warranty periods will be extended by the period of time, if any, that the Phoenix 200 HT 
Dehumidifier is out of service while awaiting covered warranty service).
UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX 200 HT 
DEHUMIDIFIER OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. 
ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE 
MADE AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THERMA- 
STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY 
PHOENIX 200 HT DEHUMIDIFIER OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR 
ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER 
DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR 
LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long an implied warranty lasts, and some do not 
allow the exclusion or limitation of incidental or consequential damages, so one or both of these 
limitation may not apply to you.

Legal Rights:

 This warranty gives you specific legal rights, and you may also have other rights which 

vary from state to state.

9

www.usephoenix.com • [email protected]

Toll-Free 1-800-533-7533

Summary of Contents for 200 HT LGR

Page 1: ...sier movement around the jobsite Recessed Condensate Hose Does not catch on obstructions and allows for dense storage setups by reducing overall width of the unit Patented Bypass Technology Increased Capacity The Phoenix 200 HT removes 5 more water than the 200 MAX Improved High Ambient Performance Patent pending technology allows superior efficiency in high ambient conditions Focused Airflow Pate...

Page 2: ...t 80 F 60 RH If used in a wet area a ground fault interrupter GFI is required If an extension cord is required it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from yo...

Page 3: ...fication This allows the condensate to be pumped 30 with the attached hose If the condensate must be pumped more than 20 feet above the unit a second pump must be added to relay the condensate If the pump fails and the unit must be used before it can be replaced the condensate can be drained by gravity The air inlet on top and the side outlet must be at least 1 foot from walls and other obstructio...

Page 4: ...eral minutes it may cycle several times until the unit warms up 3 Maintenance 3 1 Air Filter The Phoenix 200 HT is equipped with a pleated fabric air filter that must be checked regularly The standard filter is a MERV 11 high efficiency filter Operating the unit with a dirty filter will reduce the dehumidifier s capacity and efficiency and may cause the compressor to cycle off and on unnecessarily...

Page 5: ...witch defective 3 Loose connection in internal wiring No dehumidification neither blower nor compressor run with power switch ON and lit 1 Low pressure control open 2 Power switch defective 3 Loose connection in internal wiring Figure 4 Refrigeration system Some dehumidification blower runs continuously but compressor only runs sporadically 1 Unit is in defrost cycle 2 Defrost thermostat defective...

Page 6: ...n causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increase the evaporator temperature will rise and the thermostat will close to end the defrost cycle To improve performance in low temperatures refer to Section 3 for defrost timer adjustment 4 5 Condensate Pump Condensate is automatically pumped when the water lev...

Page 7: ...e compressor The contacts are closed when power is provided to the relay coil via the control circuit The control circuit includes the power switch low pressure control defrost thermostat and timer 5 Options and Accessories 4024682 Air Filter Pleated 2 x 16 x 20 57 MERV 8 4024750 Intake Flex Duct 12 x 25 Metalized Polyester 4024935 Lay Flat Duct 10 Round x 250 Roll 6 Wiring Diagram ...

Page 8: ...16 Handle Assembly 1 4026094 Item Description Qty Part No 17 Pump Purge Switch 1 4021796 18 Hour Meter 1 4021597 19 Power Switch 1 4021822 20 Skid Plate 1 4025691 21 Instruction Label 1 4025723 22 Handle Screw M10 1 5 x 35 1 1177792 Handle Washer 1 4025517 Handle Nut M10 1 5 1 1223780 Items listed below are not shown Drain Hose 25 ID X 33 long 1 4024916 Front Panel Screw 1 4 20 X 1 2 1 1096006 Wir...

Page 9: ...ing from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix 200 HT Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period appl...

Reviews: