background image

Item   Description  

Qty  

Part No.

  

Air Filter, Pleated, 2 X 6 X 20  

  

402475

2  

Cord  

  

4025078

3  

Front Panel Retaining Nut, /4-20     

4023362

4  

Wheel, 8”  

2  

4025676

 

Wheel Hub Cap  

2  

402486

 

Retaining Ring  

2  

4025454

 

Hub Cap Retaining Washer  

2  

4025295

5  

Coupling Body, /4 Tube  

  

4023080

6  

Foot 

2  

4024073

7  

Defrost Timer  

  

402823

8  

Low Pressure Control  

  

402229

9  

Filter/Drier  

  

4025087

0  

Compressor, Carlyle  

  

402223

 

(P/N EAA090A)

 

Overload, Carlyle Compressor  

  

4022476

  

Capillary Tubes  

2  

402589

2  

Defrost Thermostat  

  

402470

 

Defrost Thermostat Mounting Clip     

402648

3  

Evaporator Coil  

  

402395

4  

Accumulator  

  

4022254

5  

Top  

  

4024903

6  

Handle Assembly  

  

4026094

Item   Description  

Qty  

Part No

7  

Pump Purge Switch  

  

402796

8  

Hour Meter  

  

402597

9  

Power Switch  

  

402822

20  

Skid Plate  

  

402569

2  

Instruction Label  

  

4025723

22  

Handle Screw (M0-.5 x 35)  

  

77792

 

Handle Washer  

  

402557

 

Handle Nut (M0-.5)  

  

223780

Items listed below are not shown

Drain Hose (.25 ID X 33’ long)  

  

402496

Front Panel Screw, /4-20 X /2  

  

096006

Wire Duct Collar (Discharge)  

  

4024078

Magnet, Grain Control Cover  

  

4025728

Condenser Coil  

  

402396

Condensate Pump  

  

4023649

Motorized Impeller Fan  

  

4025076

Relay, Compressor  

  

97000

Run Capacitor, Comp. 25 μF  

  

402492

Run Capacitor, Fan, 5 μF  

  

4025224

1

2

3

13

4

5

6

7

8

9

10

11

14

12

15

16

17

18

19

21

20

22

8 Service Parts

Specifications subject to change without notice.

8

www.usephoenix.com • [email protected]

Toll-Free 1-800-533-7533

Summary of Contents for 200 HT LGR

Page 1: ...sier movement around the jobsite Recessed Condensate Hose Does not catch on obstructions and allows for dense storage setups by reducing overall width of the unit Patented Bypass Technology Increased Capacity The Phoenix 200 HT removes 5 more water than the 200 MAX Improved High Ambient Performance Patent pending technology allows superior efficiency in high ambient conditions Focused Airflow Pate...

Page 2: ...t 80 F 60 RH If used in a wet area a ground fault interrupter GFI is required If an extension cord is required it must have a minimum of 14 gauge conductors if 25 feet long or less and 12 gauge conductors if greater than 25 feet long Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from yo...

Page 3: ...fication This allows the condensate to be pumped 30 with the attached hose If the condensate must be pumped more than 20 feet above the unit a second pump must be added to relay the condensate If the pump fails and the unit must be used before it can be replaced the condensate can be drained by gravity The air inlet on top and the side outlet must be at least 1 foot from walls and other obstructio...

Page 4: ...eral minutes it may cycle several times until the unit warms up 3 Maintenance 3 1 Air Filter The Phoenix 200 HT is equipped with a pleated fabric air filter that must be checked regularly The standard filter is a MERV 11 high efficiency filter Operating the unit with a dirty filter will reduce the dehumidifier s capacity and efficiency and may cause the compressor to cycle off and on unnecessarily...

Page 5: ...witch defective 3 Loose connection in internal wiring No dehumidification neither blower nor compressor run with power switch ON and lit 1 Low pressure control open 2 Power switch defective 3 Loose connection in internal wiring Figure 4 Refrigeration system Some dehumidification blower runs continuously but compressor only runs sporadically 1 Unit is in defrost cycle 2 Defrost thermostat defective...

Page 6: ...n causing air to flow through the evaporator coil and melt the ice when the compressor is off When the air temperature and or humidity increase the evaporator temperature will rise and the thermostat will close to end the defrost cycle To improve performance in low temperatures refer to Section 3 for defrost timer adjustment 4 5 Condensate Pump Condensate is automatically pumped when the water lev...

Page 7: ...e compressor The contacts are closed when power is provided to the relay coil via the control circuit The control circuit includes the power switch low pressure control defrost thermostat and timer 5 Options and Accessories 4024682 Air Filter Pleated 2 x 16 x 20 57 MERV 8 4024750 Intake Flex Duct 12 x 25 Metalized Polyester 4024935 Lay Flat Duct 10 Round x 250 Roll 6 Wiring Diagram ...

Page 8: ...16 Handle Assembly 1 4026094 Item Description Qty Part No 17 Pump Purge Switch 1 4021796 18 Hour Meter 1 4021597 19 Power Switch 1 4021822 20 Skid Plate 1 4025691 21 Instruction Label 1 4025723 22 Handle Screw M10 1 5 x 35 1 1177792 Handle Washer 1 4025517 Handle Nut M10 1 5 1 1223780 Items listed below are not shown Drain Hose 25 ID X 33 long 1 4024916 Front Panel Screw 1 4 20 X 1 2 1 1096006 Wir...

Page 9: ...ing from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control Limitation and Exclusions If any Phoenix 200 HT Dehumidifier part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period appl...

Reviews: