Water Interconnection Revision
Reassemble by first attaching the rectifier (if present) including the
adaption. Don’t forget to apply heat conducting paste at this point. A new
M5 spring washer is recommended if the old one seem worn out. Finally
tighten the block to the front cover.
5.5.
PFC
M
ODIFICATION
If you have a PFC equipped unit, you also may exchange both Legris
fittings. They have to be the 90° angled versions. Use a 13mm wrench to
loosen and remove them, dry-clean the thread with a pipe brush or similar
and tighten the new one with 6.5Nm Torque.
Use no lubricant or thread sealant.