background image

 
 

Bestell-Nr. 99425  Ausgabe 11.2014  Version 1-0 

 
 

7.

 

Error messages on the handswitch display 

 
 

Code 

Description  

 

Remedy  

 

HOT 

Overheating has caused it to stop the 
control unit  
 

 

Wait until the control unit has cooled down 
and HOT

 

is no longer displayed  

 

00 

Internal Error Channel 1  

 

Unplug the power cord and contact your RK 
contact person 

 

01 

Internal Error Channel 2  

02 

Internal Error Channel 3  

12 

Defect Channel 1  

 

Unplug the control unit.  

 

Fix the external short circuit or plug in the 
correct motor to the motor socket that shows 
the error.  

 

Start the control unit again.  

13 

Defect Channel 2  

14 

Defect Channel 3  

24 

Overcurrent Motor M1  

 

Remove jammed objects from the driving area.  

 

Desk might be overloaded  Remove load from 
desk.  

 

Contact your RK contact person 
 

25 

Overcurrent Motor M2  

26 

Overcurrent Motor M3  

48 

Overcurrent Motor Group 1  

49 

Overcurrent Motor Group 2  

60 

Collision protection  

62 

Overcurrent Control Unit  

36 

Plug detection in Motor socket M1  

 

Plug in the correct motor to the motor socket 
that shows the error.  

 

Reset all motors.  

37 

Plug detection in Motor socket M2  

38 

Plug detection in Motor socket M3  

61 

Actuator changed  

55 

Synchronization lost motor group 1  
 

 

Remove load from desktop.  

 

Reset all motors.  

 

If error occurs after reset again, contact your 
RK contact person 

56 

Synchronization lost motor group 2  
 

67 

High voltage  
 

 

Unplug the power cord and contact the 
customer service  

70 

Motor configuration changed  
 

 

See chapter 4  

71 

Anti-Pinch configuration changed  
 

 

See the operation manual of the control unit 
Compact-e-EU on the producers homepage: 

     http://www.logicdata.at/ 

81 

Internal error  
 

 

Make a manual reset  

 

Unplug the power cord and plug it in again 
after a few seconds.  

 

If this error occurs frequently, unplug the 
power cord and contact your RK contact 
person.  

93 

Connection error in the cascaded 
network  
(The error appears on the display for 
15 seconds and then the control unit 
goes into reset mode with the display 
flashing 

000

)  

 

Check all the cable connections and try to reset 
the motors.  

 

If you cannot reset the motors, disconnect all 
the control units from the power supply. Wait 
for at least 5 seconds and then reconnect all 
the control units to the power supply. Try to 
reset the motors again.  

 

If you still cannot reset the motors, please 
contact your RK contact person 

 
You can find the original operation manual of the control unit Compact-e-EU on the producers homepage: 