Phoenix Mecano PMZ10ES Assembly Instructions Manual Download Page 9

 

 

 

 

Safety 

5.1 

Safety instructions 

 
Phoenix  Mecano  Komponenten  AG  has  constructed  this  electric  cylinder  according  to  the  current  state  of  the  art  and  existing  safety 
regulations. However, if the electric cylinder is misused and/or operated in the manner inconsistent with the intended use or if the safety 
instructions are not observed, this may result in hazards to personnel and property. Competent handling guarantees high performance 
and availability of the electric cylinder. Faults or conditions, which may impair the safety, must be rectified immediately. 
 
Every person involved in the assembly, use or operation of this electric cylinder, must have read and understood the assembly instructions. 
 
This includes: 

 

understanding the safety instructions in the text, and 

 

being familiar with the configuration and functioning of various options of operation and application. 

 
The electric cylinder may only be used, installed and operated by the designated, trained personnel. Any works on and with the electric 
cylinder may only be carried out according to this instruction. This instruction needs therefore be kept safe and close at hand in the vicinity 
of the electric cylinder. 
 
The general, national or operational safety instructions shall be observed. Responsibilities for the use, installation and operation of this 
electric cylinder must be unequivocally stipulated and observed so that no unclear situation may arise with regard to safety aspects. Before 
every commissioning, the user must ensure that no persons or objects remain in the danger area of the electric cylinder. The user may 
only operate the electric cylinder if it is in a faultless condition. Any change must be immediately reported to the nearest person responsible. 

5.2 

Special safety instructions 

 

 

Any works with the electric cylinder may only be carried out according to this instruction. 

 

The device may only be opened (installed / dismantled) by authorised specialist personnel. In case of any defect of the electric 
cylinder, we recommend to contact the manufacturer and/or send this electric cylinder for repair. 

 

Power supply must be disconnected before installation, dismantling, maintenance or troubleshooting. 

 

The re-user must prevent pinching between guiding tube and the front suspension by means of design. 

 

A proper installation of the supply lines prevents the hazards posed by this application. 

 

Only use original accessories and spare parts. 

 

The re-user must prevent potential damages caused by the failure of the end position switch-off or nut breakage by means of 
design. 

 

The electric cylinder may not be exposed to lateral forces or torques. 

 

Loss of connection between the thrust rod and guiding tube in case of a tensile load must be prevented by means of design. It 
means that, especially with suspended loads, additional safety devices (e.g.: cable, chain, etc.) must be affixed!  

 

During maintenance, only original parts must be used and installed by trained specialist personnel. 

 

For safety reasons, unauthorised modifications or changes of the electric cylinder are prohibited. 

 

The performance data of this electric cylinder determined by Phoenix Mecano Komponenten AG may not be exceeded (see 6.6 

Performance diagram

). 

 

The type plate must remain legible. The data must be retrievable without effort at any time. 

 

Safety-relevant hazard signs identify danger areas on the product. 

 

Safety-relevant devices must be tested for operability, damage and integrity on a regular basis, at least once a year. 

 

In case of an overhead installation of the electric cylinder, the fastened loads must be secured onsite against dropping. The 
danger area under the application must be marked in the documentation of the final product. 

 

The electric cylinder must immediately be put out of operation if the mains cable and/or supply line is damaged. 

 

 

Summary of Contents for PMZ10ES

Page 1: ...EN Assembly Instructions Electric cylinder PMZ10ES 2 B 017 599 Version 1 0...

Page 2: ......

Page 3: ...cylinder 7 5 Safety 8 5 1 Safety instructions 8 5 2 Special safety instructions 8 5 3 Safety signs 9 6 Product information 10 6 1 Mode of operation 10 6 1 1 Variants of power supply 10 6 1 2 Variants...

Page 4: ...nection type AP 4 017 713 22 8 3 Connection type AP 4 017 714 23 8 4 Connection type AP 4 017 715 24 8 5 Connection type AP 4 017 716 25 8 6 Connection type AP 4 017 717 26 8 7 Connection type AP 4 01...

Page 5: ...liament and the Council dd 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment IEC 60601 1 2 2014 Medical Electrical Equipment Part 1 2 Gen...

Page 6: ...e This assembly instructions help avoid hazards and downtime and guarantee and or extend the lifetime of the product Hazard warnings safety recommendations and data in these assembly instructions shal...

Page 7: ...tments to the current version of the electric cylinder In case of any inquiries please specify the type plate data Our address Phoenix Mecano Komponenten AG Hofwisenstrasse 6 CH 8260 Stein am Rhein Te...

Page 8: ...nintended use and is forbidden Phoenix Mecano Kompo nenten AG is released of liability and general operating licence of this electric cylinder becomes void in case of unintended use 4 3 Reasonably for...

Page 9: ...ylinder may only be carried out according to this instruction The device may only be opened installed dismantled by authorised specialist personnel In case of any defect of the electric cylinder we re...

Page 10: ...ylinder must be complied with while non ob servance increases the risk of an accident The General mandatory action sign indicates the necessity to exercise caution Data marked with this sign in these...

Page 11: ...rce travel speed of the electric cylinder PMZ10 M variant Versions Push force Pull force No load Rated load Version I F 10 000 N push F 10 000 N pull 5 mm s 4 mm s Version II F 5 000 N push F 5 000 N...

Page 12: ...riants of suspension Variants of rear suspension Variant 1 4 Variant 5 8 Variant Angle Dimension 1 0 10 1 0 2 0 2 45 3 90 4 135 Variant 1 4 is only available up to 5 000 N 0 45 90 135 Variant Angle Di...

Page 13: ...12 Variants of front suspension Variant 1 Variant 2 Variant 1 is only available up to 5 000 N Variant 3 Variant 4 Internal thread M12 Screw in depth 10 mm...

Page 14: ...r ratio and spindle pitch Lifting speed 5 21 mm s depending on load spindle Protection class IP 69k static IP 65 dynamic Operating voltage 12 VDC 10 16 VDC max 20 A 24 VDC 16 28 VDC max 10 A 36 VDC 28...

Page 15: ...Plugs connectors option overview Transmission Motor Connector plug Emergency adjustment Pressure equalising element Fixing adapter rear Leading spindle Guide nut Thrust tube Fixing adapter front Plug...

Page 16: ...Phoenix Mecano Komponenten AG 15 6 7 Performance chart 6 7 1 Current consumption F N F N I A 12 VDC Current force I A 24 VDC Current force...

Page 17: ...16 6 7 2 Speed M Variant with end switch unregulated v mm s Speed force F N...

Page 18: ...linder and or other components damaged It is essential to implement an emergency stop onsite which could interrupt reliably the operating voltage in the event of a failure or malfunction of the incomp...

Page 19: ...against twisting This means that a turning rotation of the pushrod or the fixed swivel head is equal to an adjustment of the end positions Attention The attachment points for installation of the elec...

Page 20: ...direction of the arrow see figure 2 Fix the suspension at the front Attention The counterpart piece may not be able to rotate The electric cylinder must be able to be rotated in the direction of the...

Page 21: ...f the electric cylinder are prohibited Safety related devices must be tested on a regular basis depending on the frequency of use however at least once a year for integrity and operability 7 6 Cleanin...

Page 22: ...Power cable sketch Brown BN Blue BU Power cable Input Output Description Green Yellow GNYE Functional earth Brown BN Operating voltage 12 V version 12 Vdc 20 24 V version 24 Vdc 10 Control The actuat...

Page 23: ...2power 3pol Input Output Description Pin 1 Brown BN Functional earth Pin 3 Red RD Operating voltage 12 V version 12 Vdc 20 24 V version 24 Vdc 10 Control The actuator extend or retract according to th...

Page 24: ...on 12 Vdc 20 24 V version 24 Vdc 10 Connection Brown to positive Blue to negative Blue BU Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Control The actuator will extend or ret...

Page 25: ...4 V version 24 Vdc 10 Connection Brown to positive Blue to negative Blue BU Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Not connected Leave unconnected Pin 2 White WH Pin 3...

Page 26: ...24 V version 24 Vdc 10 Connection Pin 3 red to positive Pin 4 black to negative Pin 4 Black BK Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Control The actuator will extend...

Page 27: ...4 Vdc 10 Connection Pin 3 red to positive Pin 4 black to negative Pin 4 Black BK Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Not connected Leave unconnected Pin 2 White WH P...

Page 28: ...positive Extend Connect brown to positive Blue BU Pin assignment M12 Signal 12pol Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power su...

Page 29: ...28 Pin 7 Black BK Not connected Leave unconnected Pin 8 Grey GY Pin 9 Red RD Pin 10 Violet VT Pin 11 Grey Pink GYPK Pin 12 Red Blue RDBU...

Page 30: ...t Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to the...

Page 31: ...xtend or retract if there is a high voltage level at the input Pin 8 Grey Extend Pin 9 Red Retract Pegel Definition Stop 0 8 V Start 8 0 V Pin 9 Red RD Pin 10 Violet VT Not connected Leave unconnected...

Page 32: ...Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to the i...

Page 33: ...tuator will extend or retract if the input is connected to the internal ground potential Pin 10 Violet Extend Pin 11 Grey Pink Retract Switching value Switched 10 Off 100 k Pin 11 Grey Pink GYPK Pin 1...

Page 34: ...ive Extend Connect Pin 3 red to positive Pin 4 Black BK Pin assignment M12 Signal 12pol Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the po...

Page 35: ...34 Pin 7 Black BK Not connected Leave unconnected Pin 8 Grey GY Pin 9 Red RD Pin 10 Violet VT Pin 11 Grey Pink GYPK Pin 12 Red Blue RDBU...

Page 36: ...l Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection...

Page 37: ...xtend or retract if there is a high voltage level at the input Pin 8 Grey Extend Pin 9 Red Retract Pegel Definition Stop 0 8 V Start 8 0 V Pin 9 Red RD Pin 10 Violet VT Not connected Leave unconnected...

Page 38: ...Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to...

Page 39: ...tuator will extend or retract if the input is connected to the internal ground potential Pin 10 Violet Extend Pin 11 Grey Pink Retract Switching value Switched 10 Off 100 k Pin 11 Grey Pink GYPK Pin 1...

Page 40: ......

Reviews: