Phoenix Mecano PMZ10ES Assembly Instructions Manual Download Page 18

 

Phoenix Mecano Komponenten AG 

 

 

17 

Life phases 

7.1 

Electric cylinder scope of delivery 

 
The electric cylinder is delivered as an individual component. The controls and manual switches and / or accessories are not included in 
scope of delivery. 

7.2 

Transport and storage 

 
The product is to be checked by suitable personnel for visible and functional damage. Damage caused by transport and storage must be 
reported to the responsible person and Phoenix Mecano Komponenten AG immediately. 
 
Commissioning damaged electric cylinders is forbidden. 
 
The ambient conditions for the storage of the electric cylinder are prescribed as follows: 

 

air must not contain oils 

 

contact with solvent-based paints must be avoided 

 

lowest / highest ambient temperature: 

–40 °C to +85 °C 

 

air pressure: from 700 to 1060 hPa 

 
Divergent ambient factors must be approved by Phoenix Mecano Komponenten AG. 
 

7.3 

Important information on installation and commissioning 

 

It  is  essential  that  you  note  and  follow  the  following  instructions.  Otherwise  persons  can  be  injured  or  the  
electric cylinder and/or other components damaged.  

 

 

 

It is essential to implement an emergency stop onsite, which could interrupt reliably the operating voltage in the event of a failure 
or malfunction of the incomplete machine! 

 

No additional holes may be made in the electric cylinder. 

 

After setting up and commissioning, it is essential that the plug of the power supply is freely accessible. 

 

The electric cylinder must not be moved to "Stop". Risk of mechanical damage. 

 

The electric cylinder may not be opened. 

 

The user must ensure that there is no danger when the power supply is active. 

 

Pinch and shear points must be avoided in the design of the applications with this electric cylinder. These must be secured and 
marked correspondingly. 

 

Automatic start-up of the electric cylinder caused by a defect is to be stopped immediately by disconnecting the power supply 
(see Emergency stop). 

 

If the supply line is damaged, the electric cylinder must be taken out of operation immediately. 

 

The  pushrod  with  suspension  must  be  secured  against  twisting.  Non-observance  leads  to  the  adjustment  of  the  stroke  end 
position. 

 

The electric cylinder has not been designed for continuous operation. The number of starts per hour determined for your appli-
cation may not be exceeded. 

 

 

Summary of Contents for PMZ10ES

Page 1: ...EN Assembly Instructions Electric cylinder PMZ10ES 2 B 017 599 Version 1 0...

Page 2: ......

Page 3: ...cylinder 7 5 Safety 8 5 1 Safety instructions 8 5 2 Special safety instructions 8 5 3 Safety signs 9 6 Product information 10 6 1 Mode of operation 10 6 1 1 Variants of power supply 10 6 1 2 Variants...

Page 4: ...nection type AP 4 017 713 22 8 3 Connection type AP 4 017 714 23 8 4 Connection type AP 4 017 715 24 8 5 Connection type AP 4 017 716 25 8 6 Connection type AP 4 017 717 26 8 7 Connection type AP 4 01...

Page 5: ...liament and the Council dd 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment IEC 60601 1 2 2014 Medical Electrical Equipment Part 1 2 Gen...

Page 6: ...e This assembly instructions help avoid hazards and downtime and guarantee and or extend the lifetime of the product Hazard warnings safety recommendations and data in these assembly instructions shal...

Page 7: ...tments to the current version of the electric cylinder In case of any inquiries please specify the type plate data Our address Phoenix Mecano Komponenten AG Hofwisenstrasse 6 CH 8260 Stein am Rhein Te...

Page 8: ...nintended use and is forbidden Phoenix Mecano Kompo nenten AG is released of liability and general operating licence of this electric cylinder becomes void in case of unintended use 4 3 Reasonably for...

Page 9: ...ylinder may only be carried out according to this instruction The device may only be opened installed dismantled by authorised specialist personnel In case of any defect of the electric cylinder we re...

Page 10: ...ylinder must be complied with while non ob servance increases the risk of an accident The General mandatory action sign indicates the necessity to exercise caution Data marked with this sign in these...

Page 11: ...rce travel speed of the electric cylinder PMZ10 M variant Versions Push force Pull force No load Rated load Version I F 10 000 N push F 10 000 N pull 5 mm s 4 mm s Version II F 5 000 N push F 5 000 N...

Page 12: ...riants of suspension Variants of rear suspension Variant 1 4 Variant 5 8 Variant Angle Dimension 1 0 10 1 0 2 0 2 45 3 90 4 135 Variant 1 4 is only available up to 5 000 N 0 45 90 135 Variant Angle Di...

Page 13: ...12 Variants of front suspension Variant 1 Variant 2 Variant 1 is only available up to 5 000 N Variant 3 Variant 4 Internal thread M12 Screw in depth 10 mm...

Page 14: ...r ratio and spindle pitch Lifting speed 5 21 mm s depending on load spindle Protection class IP 69k static IP 65 dynamic Operating voltage 12 VDC 10 16 VDC max 20 A 24 VDC 16 28 VDC max 10 A 36 VDC 28...

Page 15: ...Plugs connectors option overview Transmission Motor Connector plug Emergency adjustment Pressure equalising element Fixing adapter rear Leading spindle Guide nut Thrust tube Fixing adapter front Plug...

Page 16: ...Phoenix Mecano Komponenten AG 15 6 7 Performance chart 6 7 1 Current consumption F N F N I A 12 VDC Current force I A 24 VDC Current force...

Page 17: ...16 6 7 2 Speed M Variant with end switch unregulated v mm s Speed force F N...

Page 18: ...linder and or other components damaged It is essential to implement an emergency stop onsite which could interrupt reliably the operating voltage in the event of a failure or malfunction of the incomp...

Page 19: ...against twisting This means that a turning rotation of the pushrod or the fixed swivel head is equal to an adjustment of the end positions Attention The attachment points for installation of the elec...

Page 20: ...direction of the arrow see figure 2 Fix the suspension at the front Attention The counterpart piece may not be able to rotate The electric cylinder must be able to be rotated in the direction of the...

Page 21: ...f the electric cylinder are prohibited Safety related devices must be tested on a regular basis depending on the frequency of use however at least once a year for integrity and operability 7 6 Cleanin...

Page 22: ...Power cable sketch Brown BN Blue BU Power cable Input Output Description Green Yellow GNYE Functional earth Brown BN Operating voltage 12 V version 12 Vdc 20 24 V version 24 Vdc 10 Control The actuat...

Page 23: ...2power 3pol Input Output Description Pin 1 Brown BN Functional earth Pin 3 Red RD Operating voltage 12 V version 12 Vdc 20 24 V version 24 Vdc 10 Control The actuator extend or retract according to th...

Page 24: ...on 12 Vdc 20 24 V version 24 Vdc 10 Connection Brown to positive Blue to negative Blue BU Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Control The actuator will extend or ret...

Page 25: ...4 V version 24 Vdc 10 Connection Brown to positive Blue to negative Blue BU Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Not connected Leave unconnected Pin 2 White WH Pin 3...

Page 26: ...24 V version 24 Vdc 10 Connection Pin 3 red to positive Pin 4 black to negative Pin 4 Black BK Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Control The actuator will extend...

Page 27: ...4 Vdc 10 Connection Pin 3 red to positive Pin 4 black to negative Pin 4 Black BK Pin assignment M12 Signal 5pol Input Output Description Pin 1 Brown BN Not connected Leave unconnected Pin 2 White WH P...

Page 28: ...positive Extend Connect brown to positive Blue BU Pin assignment M12 Signal 12pol Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power su...

Page 29: ...28 Pin 7 Black BK Not connected Leave unconnected Pin 8 Grey GY Pin 9 Red RD Pin 10 Violet VT Pin 11 Grey Pink GYPK Pin 12 Red Blue RDBU...

Page 30: ...t Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to the...

Page 31: ...xtend or retract if there is a high voltage level at the input Pin 8 Grey Extend Pin 9 Red Retract Pegel Definition Stop 0 8 V Start 8 0 V Pin 9 Red RD Pin 10 Violet VT Not connected Leave unconnected...

Page 32: ...Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to the i...

Page 33: ...tuator will extend or retract if the input is connected to the internal ground potential Pin 10 Violet Extend Pin 11 Grey Pink Retract Switching value Switched 10 Off 100 k Pin 11 Grey Pink GYPK Pin 1...

Page 34: ...ive Extend Connect Pin 3 red to positive Pin 4 Black BK Pin assignment M12 Signal 12pol Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the po...

Page 35: ...34 Pin 7 Black BK Not connected Leave unconnected Pin 8 Grey GY Pin 9 Red RD Pin 10 Violet VT Pin 11 Grey Pink GYPK Pin 12 Red Blue RDBU...

Page 36: ...l Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection...

Page 37: ...xtend or retract if there is a high voltage level at the input Pin 8 Grey Extend Pin 9 Red Retract Pegel Definition Stop 0 8 V Start 8 0 V Pin 9 Red RD Pin 10 Violet VT Not connected Leave unconnected...

Page 38: ...Input Output Description Pin 1 Brown BN GND Internal ground potential of the actuator Do not connect with the power supply Pin 2 Blue BU Signal GND High resistance and capacitive coupled connection to...

Page 39: ...tuator will extend or retract if the input is connected to the internal ground potential Pin 10 Violet Extend Pin 11 Grey Pink Retract Switching value Switched 10 Off 100 k Pin 11 Grey Pink GYPK Pin 1...

Page 40: ......