CU165
Installation
92290 1.0
15
6. Installation
6.1
Safety notices to observe during installation
Basic safety rules must be followed in order to ensure that the end product can be continually op-
erated in a safe manner. These rules must be observed while using the end product and while in-
stalling the CU165 in the end product.
6.1.1
Ensuring operational reliability during installation
The safety and reliability of the end product containing DewertOkin components can be ensured by
using the proper construction methods as described below.
6.2
Installation procedure
Before installing and connecting the CU165, make sure that you are observing all of the safety no-
tices found in the "Safety notices to observe during installation" section.
6.2.1
Installing the CU165 in the end product
The CU165 can be clipped into a mounting plate. The mounting plate is screwed onto the end
product at 4 fastening points using suitable screws.
The drilling dimensions for the mounting plate, as shown in Figure 7, only illustrate an example
and are not necessarily authoritative for all applications.
Figure 7
Drilling dimensions (example): Fastening points on the mounting plate (specifica-
tions in mm)
64
96
Ø 3.3