FL SWITCH GHS
1-2
PHOENIX CONTACT
8042_en_00
1.2
Mounting of the extension module
Mounting:
1.
Place the module onto the DIN rail from above (A). The upper holding keyway must be
hooked onto the top edge of the rail. Push the module from the front towards the
mounting surface (B). Check that the positive latches have snapped on properly.
Figure 1-2
Mounting extension modules
2.
Now that the extension module is snapped onto the DIN rail, push it along the DIN rail
towards the head station (A), until the male connector/female connector of the modules
are interlatched and the sides of the modules lie flush with one another. Secure the
connection using the two screws (B).
Figure 1-3
Mounting extension modules
NOTE:
Always switch off the supply voltage when mounting/removing the extension
module.