background image

BWP 2XXXX

8

PHOENIX CONTACT

108593_en_00

1.3

Security in the network

1.4

Intended Use

The device is designed for use in the industry.

The device is state-of-the art and has been built to the latest standard safety require-

ments. However, dangerous situations or damage to the machine itself or other prop-

erty can arise from the use of this device.

The device fulfills the requirements of the EMC directives and harmonized European 

standards. Any modifications to the system can influence the EMC behavior.

If the device is used in a manner not specified by the manufacturer, the protection pro-

vided by the equipment may be impaired.

NOTE: Risk of unauthorized network access

Connecting devices to a network via Ethernet always entails the risk of unauthorized ac-

cess to the network.

Therefore, please check your application for any option of deactivating active communi-

cation channels . Setting passwords to prevent third parties from accessing the controller 

without authorization and modifying the system.

Because of the controller's communication interfaces, we advise against using the con-

troller in safety-critical applications without additional security appliances.

Please take additional protective measures according to the IT security requirements and 

the standards applicable to your application (for instance virtual networks (VPN) for re-

mote maintenance access, firewalls, etc.) for protection against unauthorized network ac-

cess.

On first request, you shall release Phoenix Contact and the companies associated with 

Phoenix Contact GmbH & Co. KG, Flachsmarktstraße 8, 32825 Blomberg in accordance 

with §§ 15 ff. AktG or German Stock Corporation Act (hereinafter collectively referred to 

as "Phoenix Contact") from all third-party claims that are made due to improper use.

For the protection of networks for remote maintenance via VPN, Phoenix Contact offers 

the mGuard product series security appliances which you can find described in the latest 

Phoenix Contact catalog (

phoenixcontact.net/products

).

Additional measures for protection from unauthorized network access can be found in the 

AH EN INDUSTRIAL SECURITY application note. The application note can be down-

loaded at 

phoenixcontact.net/products

.

NOTICE: Radio Interference

Operation of this device may cause radio interference in residential areas.

Summary of Contents for BWP 2043W

Page 1: ...Web Panels with TFT Display User manual...

Page 2: ...08593_en_00 User manual Web Panels with TFT Display 2018 10 12 Designation Revision Order No UM EN BWP 2XXXX 00 This user manual is valid for Designation Order No BWP 2043W BWP 2070W BWP 2102W 1060549...

Page 3: ...ve the purpose of technical progress The receipt of technical documentation in particular user documentation does not consti tute any further duty on the part of Phoenix Contact to furnish information...

Page 4: ...BWP 2XXXX PHOENIX CONTACT...

Page 5: ...ing the Device 11 2 2 Mounting the Device 11 2 2 1 Mounting Cutout 13 2 2 2 Side View Mounting Depth 16 2 3 Connecting the Device 19 2 3 1 Supply Voltage 19 2 4 Switching On 20 2 5 Identification 20 3...

Page 6: ...BWP 2XXXX 6 PHOENIX CONTACT 108593_en_00...

Page 7: ...with the device Observe the accident prevention rules and regulations that apply to the operating site Installation and operation must only be carried out by qualified and trained personnel This symb...

Page 8: ...nterfaces we advise against using the con troller in safety critical applications without additional security appliances Please take additional protective measures according to the IT security require...

Page 9: ...with a Linux operating system License information for the indi vidual Linux packages can be found in the web based management of the operating device 1 7 Retrieving the source code This product conta...

Page 10: ...BWP 2XXXX 10 PHOENIX CONTACT 108593_en_00...

Page 11: ...t least 30 mm 1 181 around the device to ensure sufficient air circulation NOTICE Damage When the operating device is installed horizontally please note that additional sources of heat beneath the ope...

Page 12: ...h the device from the front through the mounting cutout 3 Ensure that the gasket is properly positioned in the groove and against the panel 4 Insert the mounting clamps 1 into the recesses 2 provided...

Page 13: ...Installation and Commissioning 108593_en_00 PHOENIX CONTACT 13 2 2 1 Mounting Cutout 2 2 1 1 BWP 2043W Figure 2 2 Mounting cutout dimensions in mm A Mounting Cutout B Front Panel...

Page 14: ...BWP 2XXXX 14 PHOENIX CONTACT 108593_en_00 2 2 1 2 BWP 2070W Figure 2 3 Mounting cutout dimensions in mm A Mounting Cutout B Front Panel...

Page 15: ...Installation and Commissioning 108593_en_00 PHOENIX CONTACT 15 2 2 1 3 BWP 2102W Figure 2 4 Mounting cutout dimensions in mm A Mounting Cutout B Front Panel...

Page 16: ...CONTACT 108593_en_00 2 2 2 Side View Mounting Depth 2 2 2 1 BWP 2043W Figure 2 5 Mounting depth dimensions in mm 1 Front Panel 2 Circumferential Seal 3 Mounting Surface Thickness 1 mm to 6 mm 4 Screw...

Page 17: ...d Commissioning 108593_en_00 PHOENIX CONTACT 17 2 2 2 2 BWP 2070W Figure 2 6 Mounting depth dimensions in mm 1 Front Panel 2 Circumferential Seal 3 Mounting Surface Thickness 1 mm to 6 mm 4 Screw 5 Mo...

Page 18: ...2XXXX 18 PHOENIX CONTACT 108593_en_00 2 2 2 3 BWP 2102W Figure 2 7 Mounting depth dimensions in mm 1 Front Panel 2 Circumferential Seal 3 Mounting Surface Thickness 1 mm to 6 mm 4 Screw 5 Mounting Bra...

Page 19: ...Plug the socket strip into the pin strip on the operating device 4 Secure the socket strip against slipping out with screws 1 The device has reverse polarity protection In case of wrong polarity the...

Page 20: ...number device type 2 MAC Adress 3 Voltage and power specification Please also pay attention to the further information in the user manual of your software op tion at phoenixcontact net products See D...

Page 21: ...d or sharp objects such as pens or fingernails can lead to irreparable damages of the touch screen Exclusively therefore use the fingertips or the aids indicated in the tech nical data for the operati...

Page 22: ...BWP 2XXXX 22 PHOENIX CONTACT 108593_en_00...

Page 23: ...t periphery equipment for ex ample Mass memory printer scanner mouse keyboard etc 4 1 1 Cable 1 2 3 NOTICE Using hardware not suitable for industrial use for example keyboard mouse memory card in indu...

Page 24: ...4 1 Assignment of the Ethernet interface Pin Designation Function 1 Tx Transmitted Data Positive Polarity 2 Tx Transmitted Data Negative Polarity 3 Rx Received Data Positive Polarity 4 n c Not Connec...

Page 25: ...Maintenance and Servicing 108593_en_00 PHOENIX CONTACT 25 5 Maintenance and Servicing 5 1 Front Panel Only use a damp cloth to remove any dirt from the front panel...

Page 26: ...BWP 2XXXX 26 PHOENIX CONTACT 108593_en_00...

Page 27: ...cessing unit Arm Cortex A9 Clock frequency 1 GHz Memory RAM 1 GByte Mass storage 4 GByte eMMC Connection System Male connector strip Phoenix COMBICON 3 pin RJ45 male connector USB male connector type...

Page 28: ...6 Emitted interference IEC 61000 6 4 EN 55011 limit value class A Equipment requirements DIN EN 61131 2 Storage and transportation DIN EN 61131 2 Power supply DIN EN 61131 2 Impact load shocks IEC 600...

Page 29: ...x W in mm Inch 53 8 x 95 2 118 x 3 74 Electrical Data Supply voltage 24 V DC 15 Power consumption typical at 24 V 0 22 A Connected load 5 3 W Front Panel and Enclosure Enclosure Plastic black Front pa...

Page 30: ...n mm Inch 154 08 x 85 92 6 066 x 3 382 Electrical Data Supply voltage 24 V DC 15 Power consumption typical at 24 V 0 25 A Connected load 6 W Front Panel and Enclosure Enclosure Plastic black Front pan...

Page 31: ...in mm Inch 222 72 x 125 28 8 768 x 4 932 Electrical Data Supply voltage 24 V DC 15 Power consumption typical at 24 V 0 35 A Connected load 8 4 W Front Panel and Enclosure Enclosure Plastic black Fron...

Page 32: ...BWP 2XXXX 32 PHOENIX CONTACT 108593_en_00...

Page 33: ...nting 11 Mounting cutout BWP 2043W 13 BWP 2070W 14 BWP 2102W 15 Mounting depth BWP 2043W 16 BWP 2070W 17 BWP 2102W 18 N Nameplate 20 P Pin assignment Ethernet 24 S Safety notes 7 Servicing 25 Side vie...

Page 34: ...BWP 2XXXX 34 PHOENIX CONTACT 108593_en_00...

Reviews: