Application manual for PSRclassic and PSRmultifunction, and the modular safety relay system
PHOENIX CONTACT
102597_en_03
5.4.3
PSR-ESAM4/2x1/1x2 up to PL e/SIL 3
Three-stage enable switch with two-channel emergency stop monitoring (with
cross-circuit detection)
Application example
–
Three-stage enable switch monitoring
–
Two-channel emergency stop monitoring
–
Cross-circuit detection
–
Ground fault detection (S11, S12 only)
–
Manual reset (S12, S34) at safety relay KS1
–
Feedback of contactor contacts K3 and K4 at S34 at safety relay KS1
–
Automatic reset (S12, S35) at safety relay KS2
–
Feedback of contactor contacts K5 and K6 at S35 at safety relay KS2
–
Stop category 0
–
Monitoring of external contactors
–
Safety level of the example up to PL e (EN ISO 13849-1) and SIL 3 (EN 62061)
Figure 5-23
Three-stage enable switch with two-channel emergency stop monitoring
PSR-ESAM4/2x1
Order No.
2900525 with screw connection
2900526 with spring-cage connection
Technical data
–
24 V AC/DC
–
2 enabling current paths, 1 signaling current path
–
Manual start or autostart
–
Reinforced insulation
–
Cat. 4, PL e in accordance with EN ISO 13849-1, SILCL 3 in
accordance with EN 62061
A1
23
13
31
A2
S34
S35
24
14
32
( )
( )
PSR-ESAM4/2x1/1x2
S
S
12
11
S21
S22
(+)
( )
( )
(GND)
A1
23
13
31
A2
S34
S35
24
14
32
( )
( )
PSR-ESAM4/2x1/1x2
S
S
12
11
S21
S22
(+)
( )
( ) (GND)
M
(N)
(L1)
L+
K6
K5
41
42
31
32
23
24
13
14
1
2
3
B1
S3
K4
K3
S1
KS1
KS2
K3
K4
K5
K6
K5
K6
M
K3
K4
Enable switch
operation
Emergency
stop
operation
Reset
Emergency
stop
Summary of Contents for 2702924
Page 137: ......