Current and power data

*

BL2 ... 1000

BL2 ... 2000

BL2 ... 7000

Current consumption @ 24 V, maximum

with no display

with 12-in. display

with 15.6-in. display

with 17-in. display

1.07 A

1.33 A

1.45 A

1.78 A

1.44 A

1.64 A

1.75 A

1.95 A

1.83 A

2.19 A

2.25 A

2.50 A

Power, maximum @ 24 V, maximum

with no display

with 12-in. display

with 15.6-in. display

with 17-in. display

25.7 W

31.9 W

34.8 W

42.7 W

34.6 W

39.4 W

42.0 W

46.8 W

43.9 W

52.6 W

54.0 W

60.0 W

*

Does not include wireless mini PCIe card

Windows 10, SSD and M.2 drives, 8 GB RAM, loopback plugs in all COM and LAN ports, USB ports fully loaded, running Burn-in

®

 tests

Operating systems

Operating system (configuration option)

Windows

®

 10 IoT Enterprise LTSB 2016

Data storage

Type (configurable option)

Internal M.2 SSD 

Number of bays

1

RAID support

None

Main memory

RAM, maximum

BL2...1000

BL2...2000, BL2...7000

4 GB

8 GB

Type

DDR3L

Processor data

BL2 ... 1000

BL2 ... 2000

BL2 ... 7000

Processor

Intel Celeron N3350

Intel Pentium N4200

Intel Core i5-7442EQ

Clock speed

1.10 GHz

2.40 GHz burst

1.10 GHz

2.50 GHz

2.10 GHz

2.90 GHz

Cache

2 MB

2 MB

6 MB

Number of cores

2

4

4

Number of threads

2

4

4

Maximum TDP

6 W

6 W

25 W

Number of memory channels

2

2

2

Summary of Contents for 1016236

Page 1: ...User manual UM EN BL2 1000 2000 7000 Basicline 2 configurable industrial PCs...

Page 2: ...xcontact com 3799_en_D Basicline 2 configurable industrial PCs Designation Order No BL2 BPC 1000 2404777 BL2 PPC 1000 2404845 BL2 BPC 2000 2404844 BL2 PPC 2000 2404846 BL2 BPC 7000 1016240 BL2 PPC 700...

Page 3: ...5 3 Installation 7 3 1 Mounting 7 3 1 1 Wall mount BL2 BPC 8 3 1 2 DIN rail mount BL2 BPC 9 3 1 3 Panel mount BL2 PPC 10 3 2 Interfaces 11 3 2 1 Power connection 12 3 2 2 Serial communication 13 3 3 A...

Page 4: ...BL2 1000 2000 7000 2 36 PHOENIX CONTACT 3799_en_D B Appendixes 29 B 1 List of figures 29 B 2 List of tables 31 B 3 Index 33...

Page 5: ...ndards Any modifications to the systems can influence the EMC behavior This symbol indicates hazards that could lead to personal injury There are three signal words indicating the severity of a potent...

Page 6: ...radio interference In this case the operator is obligated to implement appropriate measures 1 3 2 Product changes Changes or modifications to hardware and software of the device are not permitted Inc...

Page 7: ...r N3350 1 10 2 40 GHz BL2 BPC 1000 2404777 1 Industrial panel PC configurable Intel Celeron processor N3350 1 10 2 40 GHz BL2 PPC 1000 2404845 1 Industrial box PC configurable Intel Pentium N4200 proc...

Page 8: ...BL2 1000 2000 7000 6 36 PHOENIX CONTACT 3799_en_D...

Page 9: ...round the heat sink to provide sufficient cooling NOTE Install the BL2 1000 2000 7000 with adequate clearance around the heat sink to provide sufficient air flow such that ambient temperatures do not...

Page 10: ...nsions shown in Figure 3 1 or Figure 3 2 and mark the locations of the holes on the mounting surface 2 Use the correct anchor type for the mounting surface and securely attach the BL2 BPC to the wall...

Page 11: ...the top edge of the mounting plate hangs on the top edge of the DIN rail 2 Rotate the BL2 BPC down against the lower edge of the DIN rail Press in until the latch snaps closed 3 Secure the device on t...

Page 12: ...tioned in the groove and against the panel 3 From the rear place the clamps 2 in the slots 3 on the display and slide the clamp to the left to lock it into the slot Clamps must be installed in every s...

Page 13: ...se ports connect the BL2 1000 2000 7000 to external digital displays with a corresponding DP connector Mini PCIe This internal slot allows installation of a mini PCIe card see Mass storage on page 21...

Page 14: ...the wire retaining screws in the connector to 0 5 Nm 4 4 lbf in Secure the connector to the BL2 1000 2000 7000 chassis Table 3 2 Power connector Pin No Description 6 Ground 0 V DC 24 V DC 20 X11 COM...

Page 15: ...the D SUB 9 connector varies with the different configuration settings Table 3 3 RS 232 422 485 communication settings Data bits Parity Stop bits RS 232 7 8 None Even Odd 1 2 RS 422 485 Autotoggle RTS...

Page 16: ...ince the BL2 1000 2000 7000 is often installed within an enclosure it may be advisable to install the antenna on the exterior of the enclosure rather than directly to the IPC To do this an appropriate...

Page 17: ...n see Figure 3 6 on page 11 Table 4 1 LED indications LED Indication Description PWR Green When 24 V DC is applied and the power switch is turned on SATA Flashes green Indicates data storage HDD or SS...

Page 18: ...BL2 1000 2000 7000 16 36 PHOENIX CONTACT 3799_en_D...

Page 19: ...e the BL2 BPC upward and off through the wide portion of key hole slot 4 Place the unit on a flat surface with the heat sink down Figure 5 1 Component access via service panel 5 Loosen and remove the...

Page 20: ...000 7000 when the system is not connected to a 24 V DC power source If power is removed while the battery is discharged or removed any user defined UEFI settings will be lost and a CMOS checksum error...

Page 21: ...page 20 6 Reinstall the service panel or reattach the case to the display panel 7 Reconnect the power connector and apply power During the boot process a message will appear notifying the user that th...

Page 22: ...ce jumper between pins 2 and 3 for 3 seconds reset position 4 Remove jumper from pins 2 and 3 and reinstall on pins 1 and 2 the run position 5 Reinstall the service panel or reattach the case to the d...

Page 23: ...move the two screws 1 securing the mounting bracket 2 Repeat for the other side 3 Remove the two screws 3 holding the side panels 4 to the chassis 5 Repeat for the other side 4 Remove the three screws...

Page 24: ...B ports During the boot process press the F2 key to enter the UEFI setup utility Use the arrow keys to navigate and highlight desired selections Follow on screen instructions and be sure to save any c...

Page 25: ...ption 5 95 non condensing 10 80 non condensing Weight BL2 BPC 1000 BL2 BPC 2000 with no display with 12 in display with 15 in display with 17 in display 1 5 kg 4 1 kg 5 7 kg 7 1 kg Weight BL2 BPC 7000...

Page 26: ...s mini PCIe card Windows 10 SSD and M 2 drives 8 GB RAM loopback plugs in all COM and LAN ports USB ports fully loaded running Burn in tests Operating systems Operating system configuration option Win...

Page 27: ...slots 1 Mini PCIe card size maximum 30 00 x 50 95 x 15 00 mm This slot is not available if ordered with the wireless option Radio module configurable Connector type Mini PCIe Device interface PCI Exp...

Page 28: ...h screen Brightness 300 Cd m Number of colors 16 2 million Backlight life minimum 50000 h Contrast ratio 700 1 View angle horizontal vertical CR 10 typ 80 70 Installation cutout dimensions width x hei...

Page 29: ...000 4 3 2002 A1 2002 Radiated radio frequency electromagnetic field immunity EN 61000 4 4 2004 EFT Burst EN 61000 4 5 1995 A1 2001 Surge immunity EN 61000 4 6 1996 A1 2001 Conducted radio frequency in...

Page 30: ...BL2 1000 2000 7000 28 36 PHOENIX CONTACT 3799_en_D...

Page 31: ...DIN rail mounting 9 Figure 3 4 Panel cutout dimensions 10 Figure 3 5 Panel mounting clamps 10 Figure 3 6 Connectors and ports 11 Figure 3 7 Power connector 12 Figure 3 8 Antenna installation 14 Sectio...

Page 32: ...BL2 1000 2000 7000 30 36 PHOENIX CONTACT 3799_en_D...

Page 33: ...X CONTACT 31 36 B 2 List of tables Section 3 Table 3 1 Display cutout dimensions 10 Table 3 2 Power connector 12 Table 3 3 RS 232 422 485 communication settings 13 Table 3 4 D SUB 9 pinout 13 Section...

Page 34: ...BL2 1000 2000 7000 32 36 PHOENIX CONTACT 3799_en_D...

Page 35: ...Cutout 10 D DIN rail mount BL2 BPC 9 Display cutout dimensions 10 D SUB 9 pinout 13 E External display 11 H Hard drive 21 I Interfaces 11 L LEDs 15 M Mass storage 21 Mounting 7 P Panel mount BL2 PPC 1...

Page 36: ...BL2 1000 2000 7000 34 36 PHOENIX CONTACT 3799_en_D...

Page 37: ...products in your specific application in particular with regard to observing the applicable standards and regulations All information made available in the technical data is supplied without any accom...

Page 38: ...products Subsidiaries If there are any problems that cannot be solved using the documentation please contact your Phoenix Contact subsidiary Subsidiary contact information is available at phoenixconta...

Reviews: