II.
LENS CLEANING
1.
Slide front lens to its extreme forward position using the control handle.
2.
Clean the front lens using glass cleaner and a soft, lint-free cloth. The rear surface
may be reached by removing the housing.
3.
Slide rear lens fully back and clean both surfaces.
4.
Replace housing.
III.
COLOR GEL REPLACEMENT
1.
Unscrew four thumbscrews on either side of the color boomerang.
2.
Lift boomerang off. Position it upside down, control levers facing you.
3.
Raise the lefthand (operator right) gel holder and lower all the others.
4.
Remove three clip fasteners around the gel holder rim.
5.
Separate rings, remove old gel.
6.
Use the ring as a pattern to cut new gel. Darker gels should be put in lefthand
(operator right) gel holders.
7.
Insert gel, cover with ring and secure with three clips.
8.
Lower lefthand (operator right) gel holder and raise next one.
9.
Repeat steps #4 to #8. To access the bottom gel clip, raise all the gels to the
left
or right and lower the one being worked on.
10.
As you move toward the right-hand gels (operator right), insert progressively
lighter colors. The lefthand (operator right) holders should be used for deep blue
or purple gels.
11.
Replace boomerang assembly and secure with four thumbscrews.
IV.
LUBRICATION
1.
R
emove
housing carry handles and mount screws
.
2.
Tighten vertical tilt lock handles on either side of yoke
.
Unit will be unbalanced
with the housing off
3.
Unscrew the two black control knobs leaving the control shafts in place.
4.
Grip
both the front and rear end
of the housing
.
5.
Lift straight up until front lens is cleared, and remove.
6.
Wipe all bearing shafts with a cloth dampened with furniture wax.
7.
Operate front and rear lenses forward and back to distribute wax.
8.
Replace housing
using the black carry handles
. Guide front over lens and line
up front
housing and chassis.
9.
Replace the two black control knobs
.
10.
Re-assemble the carry handles and chassis mount screws
.
V.
TROUBLESHOOTING-LAMP AND BALLAST
Lamp does not light:
1.
If unit is off, check power and fuse. Replace fuse with 7 amp 3AB fuse.
2.
If unit is on and the fan is running, check the following:
(a)
Check that the
LED
module connections
are in place and secured
. Lamp
may be
defective or reached the end of its life.
(b)
The power supply contains no user serviceable parts. Contact Phoebus Mfg.